DECAN_S2_Trouble(Eng_Ver4.2).pdf - 第122页

1-100 Advanced Chip Shooter DECAN S2 T roubleshooting Guide $6009 Can't find the Z axis PORT. [FREEZ E LEVEL] [Problem]  Can not find the port of Z-axis motor due to fault in equipment setup or software problem. [S…

100%1 / 200
1-99
System Messages of the MMI and Solutions
When the part size is smaller than 1005 (including 1005), if the nozzle picks a part up
at the edge, it is highly possible that the part stands vertically when it is placed even
though the vision system recognized the part normally. This error occurs mainly when
the calibration of the part measured by the vision system exceeds the value set by the
equipment.
[Solution]
Check if the state and pickup position of the part in the feeder is appropriate.
In the case of excessive part dumping, contact our designated C/S or local agent.
1.4.10. ANC Related Error [$6000~$65ff]
$6002 Can't open the ANC. [EMER LEVEL]
$6003 Can't close the ANC. [FREEZE LEVEL]
[Problem]
The ANC can't be opened due to mechanical interference. ($6002)
The ANC can't be closed due to mechanical interference. ($6003)
The position of the ANC sensor is incorrect.
[Solution]
Turn off the Buzzer by pressing the “STOP” button.
Switch the machine to “IDLE” mode by pressing the “RESET” button.
Check if there is any mechanical interference.
Check on the ‘I/O’ of the Diagnosis menu if shutter of the ANC operates correctly and
detected by the sensor. Check it during manual operation. To perform manual
operation, click the <Shutter Open/Close> button on the ANC menu.
Check the position of the sensor.
$6004 XY couldn't move to the nozzle put position. [FREEZE LEVEL]
[Problem]
An error occurred while the head was moving to the corresponding position to change
the nozzle automatically.
[Solution]
Turn off the Buzzer by pressing the “STOP” button.
Switch the machine to “IDLE” mode by pressing the “RESET” button.
Check the XY-Axis board.
Check the wiring related to XY. Please refer to the servo interface (x, y1, y2) drawings
of the “Technical Reference”.
1-100
Advanced Chip Shooter DECAN S2 Troubleshooting Guide
$6009 Can't find the Z axis PORT. [FREEZE LEVEL]
[Problem]
Can not find the port of Z-axis motor due to fault in equipment setup or software
problem.
[Solution]
Check motor setup value from the ‘Confg.DB’ file in the mark3/system/ directory.
Check motor setup value in the ‘Factory Setup’. (Factory setup value)
If any problem occurs, contact the C/S company designated by Hanwha Precision
Machinery Co., Ltd. or the local agent.
$600a Couldn't move to the position of nozzle pick. [FREEZE LEVEL]
[Problem]
An error occurred when the head moved to the corresponding position to change the
nozzle automatically.
[Solution]
Perform [Solution] in $6004.
$600c No nozzle ID in the component Data. [FREEZE LEVEL]
[Problem]
In the component data, there is no nozzle related setting.
[Solution]
Turn off the Buzzer by pressing the “STOP” button.
Switch the machine to “IDLE” mode by pressing the “RESET” button.
Click ‘Common Data’ of corresponding component on the ‘Part’ of the PCB Edit
menu, and register the nozzle to work on in the nozzle 1.
1-101
System Messages of the MMI and Solutions