System Messages of the MMI and Solutions
problem, contact our designated C/S or local agent. (Replace sensor dog or lever.)
E0027 A part has not been fed due to insufficient vibration of the vibration feeder
[Cause]
Insufficient vibration of the vibration feeder
[Measures]
Set the position of the vibration diaphragm so that the vibration strength increases
For further details, refer to the following documents:
Technical Reference : Vibration Feeder
E0030 Tape vinyl is twisted inside the tape feeder
[Cause]
Incorrect installation of cover vinyl on the tape guide.
[Measures]
Check whether the upper cover tape is rolled into the tape guide after being peeled off.
If it has a problem, install the tape reel in the tape feeder referring to the tape feeder
manual.
E0031 Defective discharge of tape vinyl
[Cause]
1) Defective tape reel connection
2) There are many foreign materials in the vinyl discharge slot of the tape guide
3) The rear door of the vinyl box does not open smoothly
4) There are many cohesive foreign materials on the vinyl discharge gear
5) Adhesive force of the vinyl itself is particularly strong.
6) Drain spring is damaged or slipped out.
7) Since the vinyl discharge gear bearing has been damaged, it rotates reversely
8) A component of the link is damaged
[Measures]
1) Splice the vinyl using the vinyl splicing tape and tip provided by us. (Refer to the tape
feeder manual)
2) Check and clean the vinyl slot of the tape guide.
3) Contact our designated C/S company or local agent.
4) Clean the vinyl discharge gear.
5) If the adhesive vinyl is not used, or if it is used with the door open, remove the vinyl
inside frequently.

1-12
Advanced Chip Shooter DECAN S2 Troubleshooting Guide
6) Check for the spring visually and if it is slipped out, place the spring at the right
position again. If the spring is damaged or deformed, contact our designated C/S
company or local agent.
7) Contact our designated C/S company or local agent. (Replace the bearing of the vinyl
discharge gear.)
8) Contact our designated C/S company or local agent. (Replace link)
E0040 A part is stuck in the tape discharge path.
[Cause]
Foreign materials exist on the tape discharge path
[Measures]
After lifting the locker sufficiently while pressing the locker limit pin, correct the
carrier tape and return the locker to the normal position.
E0050 Pickup Z setup error occurred.
[Cause]
Pickup height setup is incorrect.
[Measures]
Adjust the pickup Z height and pickup speed.
E0051 The down movement for pickup is fast.
[Cause]
The part to be placed using the Soft Touch function was placed in the high speed
mode.
[Measures]
Set the Soft Touch function and use it.
E0100 Vacuum Sensor Board The vacuum pressure of the head’s pneumatic system is low
due to a defective component
[Cause]
1) Defective solenoid valve
2) Defective Vacuum Pump (Applied only to the SM471, 481, DECAN F2 machine.)
3) Damaged tube and fitting
[Measures]
1) Perform solenoid valve operation test. If a problem occurs, contact our local agent.
(Replace the solenoid valve.)
2) Check whether the vacuum level of the front vacuum gauge is -90kPa. If a problem
occurs, contact or our local agent. (Replace the Vacuum Pump.)

1-13
System Messages of the MMI and Solutions
3) Check whether the tube and fitting are damaged. If a problem occurs, contact or our
local agent. (Replace the Tube and Fitting.)
E0101 Vacuum pressure is low due to contaminated vacuum air line
[Cause]
1) Fouled head vacuum filter
2) Fouled Air Tube, Ball Splin
[Measures]
1) Contact our designated C/S company or local agent. (Replace the vacuum filter)
2) Open the 'Pneumatic Pressure Diagnosis' dialog box of the MMI and insert the CN040
nozzle into the nozzle holder. Then turn on the vacuum system. The normal head
vacuum level is 600~700mmHg with the nozzle end covered with a hand. (The nozzle
and vacuum level differ by machine.)
E0102 Low vacuum pressure due to an oil leak into the vacuum generator
[Cause]
Fouled vacuum generator filter (Except for machines applying a vacuum pump)
[Measures]
Contact our designated C/S company or local agent.(Replace the vacuum generator)
E0103 Vacuum is not generated due to a defective connection cable of the vacuum solenoid
valve
[Cause]
The solenoid valve power supply cable is not connected properly.
[Measures]
Check that the solenoid valve power supply line is properly connected. If it has a
problem, contact or our local agent. (Replace the head vacuum solenoid power supply
cable.)
E0104 Vacuum is not generated due to a defective connector of the solenoid valve in front of
the vacuum generator
[Cause]
The connector of the solenoid valve in front of the vacuum generator is not connected
properly
[Measures]
Reassemble the connector of the solenoid valve in front of the vacuum generator.
E0105 Vacuum is not generated due to a defective head I/O board
[Cause]