DECAN_S2_Trouble(Eng_Ver4.2).pdf - 第154页

1-132 Advanced Chip Shooter DECAN S2 T roubleshooting Guide  Perform [Sol ution] in $a610. $a674 Failure to locate the end pin of the right lead group. [Problem]  Failed in d etailed recognition of component lead.  Th…

100%1 / 200
1-131
System Messages of the MMI and Solutions
The component lead is defective.
Incorrect registration the number of leads in the component data.
The component data and lighting setup is inadequate.
[Solution]
The component data and lighting setup is inadequate.
Perform [Solution] in $a610.
$a671 Failure to locate the end pin of the upper lead group.
[Problem]
Failed in detailed recognition of component lead.
Failed in detailed recognition of component lead.
Incorrect registration the number of leads in the component data
The component data and lighting setup is inadequate.
[Solution]
Check if the component lead is defective.
Perform [Solution] in $a610.
$a672 Failure to locate the end pin of the left lead group.
[Problem]
Failed in detailed recognition of component lead.
The component lead is defective.
Incorrect registration the number of leads in the component data.
The component data and lighting setup is inadequate.
[Solution]
Check if the component lead is defective.
Perform [Solution] in $a610.
$a673 Failure to locate the end pin of the lower lead group.
[Problem]
Failed in detailed recognition of component lead.
The component lead is defective
Incorrect registration the number of leads in the component data.
The component data and lighting setup is inadequate.
[Solution]
Check if the component lead is actually defective.
1-132
Advanced Chip Shooter DECAN S2 Troubleshooting Guide
Perform [Solution] in $a610.
$a674 Failure to locate the end pin of the right lead group.
[Problem]
Failed in detailed recognition of component lead.
The component lead is defective.
Incorrect registration the number of leads in the component data.
The component data and lighting setup is inadequate.
[Solution]
Check if the component lead is actually defective.
Perform [Solution] in $a610.
$a712 <WARNING> Can not find the first(upper side)lead of left side lead group.
[Problem]
<WARNING> Can not find the first(upper side)lead of left side lead group.
[Solution]
Turn off power to the machine in the usual way. Wait 5 seconds, turn back on and
reboot the system.
$a723 <WARNING> Can not find the first(left side) lead of lower lead group.
[Problem]
<WARNING> Can not find the first(left side) lead of lower lead group.
[Solution]
Turn off power to the machine in the usual way. Wait 5 seconds, turn back on and
reboot the system.
$a811 Can not calculate the angle of component while recognizing component.
[Problem]
The shape of component is circular.
The angle cannot be calculated due to hardware or software problem.
[Solution]
When the shape of component is circular, register the component as ‘CHIP-Circle’
type.
$a822 Width (X value) of the component does not match with the registered value.
[Problem]
1-133
System Messages of the MMI and Solutions
Occurs when there is big difference between the recognized component width and
registered value.
Defective component.
The component data and lighting setup is inadequate.
[Solution]
Check if the component is defective.
Perform [Solution] in $a610.
$a823 Height of the component(Y value) does not match with the registered value.
[Problem]
Occurs when there is big difference between the recognized component width and
registered value.
Defective component.
The component data and lighting setup is inadequate.
[Solution]
Check if the component is defective.
Perform [Solution] in $a610.
$a824 Center of the component is deviating too much from the nozzle center in X direction.
[Problem]
The component is recognized, but it is too much offset.
Pickup position or pickup condition of the component is inadequate.
[Solution]
Check through SMVision window to determine the pickup position of the
corresponding component in the Feeder of the “PCB Edit” menu.
$a825 Center of the component is deviating too much from the nozzle center in X direction.
[Problem]
The component is recognized, but it is too much offset.
Pickup position or pickup condition of the component is inadequate.
[Solution]
Check through SMVision window to determine the pickup position of the
corresponding component in the Feeder of the “PCB Edit” menu.
$a826 Angle of the component is too wide.
[Problem]
Recognized angle of the component exceeds the registered range.