1-83 System Messages of the MMI and Solutions $4655 The fiducial camera %d cannot move to this zone. [FREEZE LEVEL] [Problem] Failed to move th e fiducial camera to recognize the barcode on the PCB. Incorrect teachin…

1-82
Advanced Chip Shooter DECAN S2 Troubleshooting Guide
$4621 Failed to find the fiducial while performing the gantry thermal mapping. [EMER
LEVEL]
[Problem]
Failed to recognize the fiducial mark for calibration while performing the gantry
thermal mapping.
[Solution]
Take measures same as those against the error code “$4611”.
$4623 The calibration of the fifucial carmer scale was not performed. - Gantry Thermal
Mapping [EMER LEVEL]
[Problem]
The scale calibration of the fiducial camera to be used was not performed while
performing the gantry thermal mapping.
[Solution]
Take measures same as those against the error code “$4612”.
$4650 The fiducial camera failed to find the fiducial mark of the PCB. [EMER LEVEL]
$4651 The fiducial mark cannot move through this area. [EMER LEVEL]
[Problem]
The fiducial camera failed to move to find the fiducial mark.
[Solution]
Check if the fiducial camera can move to the position of the corresponding fiducial
mark.
$4652 There is great difference between the coordinate of the fiducials recognized by the
fiducial camera and that of the fiducial taught by the fiducial camera.. [EMER
LEVEL]
[Problem]
The difference in the distance between measured fiducials is greater than the
designated distance. (Greater than 1mm at least)
[Solution]
Check if the CAD data of the fiducial mark for the PCB that is being worked on is
correct.
If the CAD data of the fiducial mark for the PCB that is being worked on is correct,
check if the PCB that is worked on currently is warped or the fiducial mark is out of
the normal position.
If the PCB is warped or the fiducial mark is out of the normal position, it cannot be
worked on. Therefore, remove it and continue to work on another PCB.

1-83
System Messages of the MMI and Solutions
$4655 The fiducial camera %d cannot move to this zone. [FREEZE LEVEL]
[Problem]
Failed to move the fiducial camera to recognize the barcode on the PCB.
Incorrect teaching of the barcode position.
[Solution]
Move the fiducial camera to the barcode position in the barcode dialog box of the
‘PCB Edit’ menu.
Recheck the barcode recognition position and input it correctly.
$4700 The head cannot move to the dump position. [EMER LEVEL]
[Problem]
The corresponding head failed to move to the dump position.
[Solution]
Check if it is possible to move the position of the dump box for the part picked up by
the corresponding head.
Check if there is any interference with the movement of the Z axis and Mirror axis of
the corresponding head or the movement of the corresponding gantry and if the XY
axes limit sensor works correctly.
If the dump box is at the position that can be moved and if the problem occurs
continuously even though each axis has no problem for operation, contact our
designated C/S company and local agent.
$4701 A vacuum error occurred when the head dumped the part (Failed to dump the part).
[EMER LEVEL]
[Problem]
Although the part was dumped, the checking by pneumatic pressure indicated that the
part failed to be dumped.
[Solution]
Check if there is a part remaining at the corresponding head. If a part still remains at
the head, it means that it was not dumped due to dirt, static electricity, etc. Check the
blow path of the nozzle and head.
Check the cleaned state of the nozzle.
Check the cleaned state of the vacuum filter for the head.
Check if the spindle is clogged.
Check if the Vacuum / Blow operate normally in the IO dialog box.
Check if the Vacuum / Blow operate normally in the IO dialog box.
Despite the above checking, if a problem occurs continuously with the part not being
dumped properly, contact our C/S company and local agent.

1-84
Advanced Chip Shooter DECAN S2 Troubleshooting Guide
$4750 The dipping area of the flux unit is too small. [FREEZE LEVEL]
[Problem]
The dipping area of the part defined in the installation information of the flux feed unit
is smaller than the part to be dipped.
[Solution]
Check that the size of the part to be dipped is identical to the size defined by the flux
feed unit. (Default value is less than • 17mm)
If the problem occurs again despite that the part is as large as the reference, contact our
designated C/S company or local agent.
$4751 Cannot access the flux feed unit. Check the position. [FREEZE LEVEL]
[Problem]
The head cannot move to the dipping position (X, Y) set by the flux feed unit.
[Solution]
Check that the dipping position (X, Y) set by the flux feed unit is appropriate. If the
position value is incorrect, perform teaching again.
Install the flux feed unit after moving it to the feeder base slot which the head can
access and then teach the dipping position (X, Y) again.
If the problem occurs continuously, contact our designated C/S or local agent.
$4752 The head cannot move to the Head $H Flux position. [FREEZE LEVEL]
[Problem]
The head cannot move due to an error related to the motor when the head moves to the
flux feed unit or it moves to another position from the flux feed unit.
[Solution]
Check if the hardware has any problem.
Check if the motor speed parameter is correct.
If the problem occurs continuously, contact our designated C/S or local agent.
$4753 Flux feed unit is not registered [FREEZE LEVEL]
[Problem]
The equipment has no information on the flux feed unit due to system data error.
[Solution]
contact our designated C/S or local agent.