DECAN_S2_Trouble(Eng_Ver4.2).pdf - 第140页

1-118 Advanced Chip Shooter DECAN S2 T roubleshooting Guide $a211 Previous vision command is not completed. [EMER LEVEL] [Problem]  An error occurr ed while recognizing components with the fly ing camera due to H/W prob…

100%1 / 200
1-117
System Messages of the MMI and Solutions
Check the state of the flying camera, cable and vision board. If any problem occurs,
contact the C/S company designated by Hanwha Precision Machinery Co., Ltd. or the
local agent.
Calibrate camera calibration. Please refer to section “Camera Calibration” on the
12.3.10 Head & Camera Calibration” of the ” Administrator’s Guide”.
In order to confirm if the component data is normal, select the error occurred
component in “Part” of the “PCB Edit” menu and check if the information contained
in the <Align Data> group is set up in the Profile Editor correctly.
1-118
Advanced Chip Shooter DECAN S2 Troubleshooting Guide
$a211 Previous vision command is not completed. [EMER LEVEL]
[Problem]
An error occurred while recognizing components with the flying camera due to H/W
problem or S/W problem.
[Solution]
Perform [Solution] in $a210.
$a212 ‘Time Out Error’ of the recognition by the flying camera.
[Problem]
The time for the flying camera to recognize the component exceeded 24.000 seconds.
[Solution]
Perform [Solution] in $a210.
$a213 ‘Time Out Error’ of the recognition by the flying camera.
[Problem]
An error occurred while recognizing components with the flying camera due to H/W
problem or S/W problem.
[Solution]
Perform [Solution] in $a210.
$a220 Recognition by the upward camera is not completed.
[Problem]
An error occurred while recognizing components with the flying camera due to H/W
problem or S/W problem.
[Solution]
Turn off power to the machine in the usual way. Wait 5 seconds, turn back on and
reboot the system.
$a221 An error occurred while the upward camera performed recognition.
[Problem]
An error occurred while recognizing components with the flying camera due to H/W
problem or S/W problem.
[Solution]
Check if component data are correct.
Check that the illumination is appropriate.
Check the LED status of the camera.
Check the camera cable.
1-119
System Messages of the MMI and Solutions
$a300 Previous vision command is not completed.
[Problem]
Occurs while trying to execute the command of other vision prior to the completion of
the current vision due to fault in the hardware or software.
[Solution]
Turn off power to the machine in the usual way. Wait 5 seconds, turn back on and
reboot the system.
$a401 Incorrect camera ID.
[Problem]
Incorrect camera ID was received due to H/W problem or S/W problem.
[Solution]
Turn off power to the machine in the usual way. Wait 5 seconds, turn back on and
reboot the system.
$a402 An internal error occurred during vision processing.
[Problem]
An error occurred while performing the internal function of vision due to H/W
problem or S/W problem.
[Solution]
Turn off power to the machine in the usual way. Wait 5 seconds, turn back on and
reboot the system.
$a403 Can not generate fiducial data due to wrong fiducial type.
[Problem]
An undefined fiducial type is used.
[Solution]
Click the <Fiducial Mark …> button in the “Board” dialog box of the PCB edit menu.
Then check and correct the data related to the corresponding fiducial mark setup.
Please refer to section “6.3 Fiducial Mark Setup” of the Administrator’s Guide.
$a404 Fiducial is not registered.
[Problem]
The system attempted to use the fiducial while it was unregistered due to H/W
problem or S/W problem.
[Solution]