1-144 Advanced Chip Shooter DECAN S2 T roubleshooting Guide The threshold va lue is too low . The nozzle is severely da maged. [Solution] Increase the threshold value on the ‘PCB Edit Part’ of the MMI or check the …

1-143
System Messages of the MMI and Solutions
The tolerance H of the component was set up too small.
The nozzle is contaminated with foreign matter.
[Solution]
Check if the component was correctly picked up.
Select the error occurred component in “Part” of the “PCB Edit” menu, and check if
the ‘Body X’ at ‘Profile Editor’ has been correctly input.
Select the error occurred component in “Part” of the “PCB Edit” menu, and enter 30%
as the tolerance H in the ‘Profile Editor’.
Remove foreign matter from the nozzle, if any.
Please refer to the [Solution] in $a635.
$aa1e Width of the component is less than reference value.
[Problem]
The component was not picked up.
Incorrect input of the ‘Body X’ of the component.
Too low setup of tolerance L of the component.
The nozzle is contaminated with foreign matter.
[Solution]
Check if the component was correctly picked up.
Select the error occurred component in “Part” of the “PCB Edit” menu, and check if
the ‘Body X’ at ‘Profile Editor’ has been correctly input.
Select the error occurred component in “Part” of the “PCB Edit” menu, and enter 30%
as the tolerance L in the ‘Profile Editor’.
Remove foreign matter from the nozzle, if any.
Please refer to the [Solution] in $a635.
$aa1f Did not pickup the component.
[Problem]
The component was not picked up.
[Solution]
Check if the component is remaining in the corresponding feeder.
If the component is remaining in the corresponding feeder, readjust the pickup
position. Check the pickup position of the corresponding component through the
VisFrame window in “Feeder” of the “PCB Edit” menu.
$aa21 There is a problem with threshold. Set the value higher manually.
[Problem]

1-144
Advanced Chip Shooter DECAN S2 Troubleshooting Guide
The threshold value is too low.
The nozzle is severely damaged.
[Solution]
Increase the threshold value on the ‘PCB Edit Part’ of the MMI or check the status of
nozzle.
Please refer to the [Solution] in $a635.
$aa22 There is a problem with threshold. Set the value higher manually.
[Problem]
The threshold value is too low.
The nozzle is severely damaged.
[Solution]
Select the error occurred component in “Part” of the “PCB Edit” menu and increase
the threshold value or check the nozzle state in the “Profile Editor”.
Please refer to the [Solution] in $a635.
$ab00 Incorrect angle has been transmitted from the VME.
[Problem]
When incorrect angle has been transmitted from the VME.
[Solution]
Turn off power to the machine in the usual way. Wait 5 seconds, turn back on and
reboot the system.
$ab01 Incorrect algorithm number has been transmitted from the VME.
[Problem]
An incorrect algorithm method has been transmitted from the VME.
[Solution]
Turn off power to the machine in the usual way. Wait 5 seconds, turn back on and
reboot the system.
$ab02 In the case of checking the heat, the number of lower lead shall be more than two.
[Problem]
In the case of checking the heat, the number of lower lead is one, although it shall be
two.
[Solution]
When the lower lead is in one piece, select the error occurred component in “Part” of
the “PCB Edit” menu, and release if “Heat” is ticked on the ‘Align Data’ of the
“Profile Editor”.

1-145
System Messages of the MMI and Solutions
$ab09 The lead size is too large.
[Problem]
Occurs when recognizing the lead larger than the one that can be recognized by the
current camera.
[Solution]
Recognize the error occurred component using a camera having larger FOV than the
present camera.
$ab0b Width of lead has deviated from the reference size.
[Problem]
Incorrect input of lead width.
[Solution]
Select the error occurred component in “Part” of the “PCB Edit” menu, check the lead
width on the “Profile Editor”, and accurately input the width.
$ab0d Incorrect number of leads.
[Problem]
Incorrect number of leads was inputted.
[Solution]
Select the error occurred component in “Part” of the “PCB Edit” menu, check the
“Lead Num” on the “Profile Editor”, and input the accurate number of leads.
$ab13 Height of component has deviated from the reference size.
[Problem]
Incorrect input of component height.
[Solution]
Select the error occurred component in “Part” of the “PCB Edit” menu and enter the
height of the component accurately on the “Profile Editor”.
$ab15 Pitch of upper lead deviated from reference value.
$ab16 Pitch of lower lead deviated from the reference value.
[Problem]
The pitch of the upper lead is different from the reference value.($ab15)
The pitch of lower lead is different from the reference value.($ab16)
[Solution]
Select the error occurred component in “Part” of the “PCB Edit” menu, check the
“Lead Pitch” on the “Profile Editor”, and input the accurate number of leads.