1-3 System Messages of the MMI and Solutions Normal Part Supply A pickup error occurred Cause Description Remarks Low vacuum pressure / delay ed vacuum creation A component of the head’ s pneumatic syste m is defecti…

1-2
Advanced Chip Shooter DECAN S2 Troubleshooting Guide
1: Machine Status Indication Area
1.2. Process Trouble Shooting
1.2.1. Pickup Error (Increased Dump Rate)
Parts are not picked up - Errors causing parts to not be picked up [Refer to Section
1.2.1.1]
Part Supply Error
Cause Description Remarks
Tape installation error Incorrect installation of tape reel in the
tape feeder
E0000
Part turnover/edge-
standing
Defective reel E0010
The tape guide has been magnetized E0011
Tape guide/Tape guide shutter
deformation
E0012
Defective tape feeder shutter operation E0013
Defective part feeding speed (odd shaped
part feeder)
E0014
Defective feeding Insufficient tape feeder maintenance E0020
Defective tape feede
r motor operation E0021
Defective tape feeder cylinder operation E0022
Insufficient feeding force of the feeder E0023
Spring damage and separation E0024
Pitch error E0025
Defective index sensor E0026
Part has not been fed due to insufficient
vibration of the vibration feeder
E0027
Defective vinyl discharge The tape vinyl has been curled inside the
tape guide
E0030
Abnormal vinyl discharge E0031
Tape jamming A part is
stuck in the tape discharge path E0040
A part beside the
corresponding part
jumped off
Pickup Z setup error E0050
Fast down movement for pickup E0051

1-3
System Messages of the MMI and Solutions
Normal Part Supply
A pickup error occurred
Cause Description Remarks
Low vacuum
pressure / delayed
vacuum creation
A component of the head’s pneumatic system
is defective
E0100
Vacuum air line is contaminated E0101
Low vacuum pressure due to an oil leak into
the vacuum generator
E0102
Defective contact of the head vacuum solenoid
cable connector
E0102
Defective assembly of the solenoid valve
connector in front of the vacuum generator
E0104
Defective head I/O board E0105
Defective vacuum sensor board E0106
Air leak
s from (Rotary joint, Coil Tube or
Fittings, Vacuum Sensor Board
E0107
Main pneumatic pressure setup error E0108
Blow setup error E0109
Incorrect Vac Delay setup E0110
Pickup position
Error
Incorrect XY coordinates of the pickup point
due to ball spline deformation
E0120
Incorrect setup of the XY coordinates of the
pickup point (Tape, Vibration, Tray Feeder)
E0121
Incorrect tape guide position E0122
Splicing err
or E0123
Incorrect Y position for pickup when installing
tape
E0124
Incorrectly set X coordinate for pickup when
installing tape
E0125
Incorrect pickup position adjustment E0126

1-4
Advanced Chip Shooter DECAN S2 Troubleshooting Guide
Incorrect feeder base adjustment E0127
Part wear/distortion in the feeder E0128
Sprocket, ratchet, etc., are contaminated with
foreign materials.
E0129
Incorrect setup of the part supply position
according to tray shape and part
characteristics
E0130
Incorrect setup of Z and Pick Z values E0131
Foreign materials in the feeder base slot and
clamp
E0132
Incorr
ect Z offset setup E0133
Z Offset change E0134
Problem with
Nozzle
Standard nozzle not used E0140
Damaged nozzle tip, abnormal nozzle spring
tension
E0141
Insufficient nozzle maintenance E0142
Use of nozzle unsuitable for the part E0143
A number of odd
shaped materials
have dropped
Vacuum check setup error E0150
A part dump error
occurred.
Parts are not dumped properly due to incorrect
blow pressure setup
E0160
Cause Description Remarks