System Messages of the MMI and Solutions
$6040 Z axis couldn't move to the put position. [FREEZE LEVEL]
[Problem]
Errors occurred while moving down the Z-axis for the nozzle ‘Put’ operation.
[Solution]
Check the position of the corresponding ANC hole and Z-axis offset.
For the ANC position check, refer to the ‘ANC hole position check’ in the
[Countermeasure] in $6030. Ensure if the Z-axis offset value of the corresponding
head is correctly set up.
For calibration of the Z-axis offset, refer to the “12.3.10.2 Head Z / R Offset
Calibration” in the “Administrator’s Guide”.
$6050 Z axis couldn't move to a safe height after putting. [FREEZE LEVEL]
[Problem]
Errors occurred while moving up the Z-axis for the nozzle ‘Put’ operation.
[Solution]
Perform [Solution] in $6040.
$6060 Can't get, nozzle in the head. [FREEZE LEVEL]
[Problem]
Nozzle actually exists when trying to get nozzle.
[Solution]
Turn off the Buzzer by pressing the “STOP” button.
Switch the machine to “IDLE” mode by pressing the “RESET” button.
1-108
Advanced Chip Shooter DECAN S2 Troubleshooting Guide
Check the existence of nozzle for the corresponding head.
Press the “READY” button to supply power to the machine.
Although a nozzle is actually mounted on the corresponding head, if it is setup not to
have been mounted on the error occurred head in the dialog box of the ANC menu,
tick the ‘No real motion (Manual)’ and after selecting the error occurred head, select
the ANC hole where the nozzle is put on the head. Then set up the ANC once more by
clicking the <Pick> button.
$6070 No nozzle in the head. Can't get. [FREEZE LEVEL]
[Problem]
Mismatch of ANC hole center after nozzle get operation, or nozzle does not exist in
the head due to inadequate height setup.
Vision nozzle check has not performed properly.
[Solution]
Perform [Solution] in $6030.
$6080 Z axis couldn't move to the get position. [FREEZE LEVEL]
[Problem]
Errors occurred while moving down the Z-axis for the nozzle ‘Get’ operation.
[Solution]
Perform [Solution] in $6040.
$6090 Z axis couldn't move to a safe height after getting. [FREEZE LEVEL]
[Problem]
Errors occurred while moving up the Z-axis for the nozzle ‘Get’ operation.
1-109
System Messages of the MMI and Solutions
[Solution]
Perform [Solution] in $6040.
$6520 Can't put, no nozzle in the Head. [EMER LEVEL]
[Problem]
Same error as $6020 occurred during manual operation.
[Solution]
Please refer to [Problem] and [Solution] in $6020.
$6530 Nozzle in the Head. Couldn't put. [EMER LEVEL]
[Problem]
Same error as $6030 occurred during manual operation.
[Solution]
Please refer to [Problem] and [Solution] in $6030.
$6560 Can't get, nozzle in the Head. [EMER LEVEL]
[Problem]
Same error as $6060 occurred during manual operation.
[Solution]
Please refer to [Problem] and [Solution] in $6060.
$6570 No nozzle in the Head. Couldn't get. [EMER LEVEL]
[Problem]
Same error as $6070 occurred during manual operation.
[Solution]
Please refer to [Problem] and [Solution] in $6070.
$6571 The type of nozzle on the head $H does not correspond to the set nozzle. [FREEZE
LEVEL]
[Problem]
The result of vision nozzle type check after replacement of the head nozzle shows that
the nozzle does not correspond to the set nozzle.
[Solution]
Check that the nozzle in use corresponds to the set nozzle.
Check the internal and external diameters of the nozzle from the ‘Device’ submenu of
the ‘System Setup’ menu.
If the problem occurs continuously, contact our designated C/S or local agent.