1-113 System Messages of the MMI and Solutions  If the problem occurs c ontinuously , contact our designate d C/S or local agent. $7000 Component alignment method not supported by this equipment. [EMER LEVEL] [Problem] …

100%1 / 200
1-112
Advanced Chip Shooter DECAN S2 Troubleshooting Guide
1: Pressure Decrease (Counterclockwise)
2: Pressure increase (Clockwise)
With the CN040 nozzles inserted into the nozzle, execute the Vacuum dialog box of
the Diagnostic and close up the nozzle hole using a finger. Then press the Vacuum On
to check if the vacuum is 500 mmHg and above.
If it is below 500 mmHg, check if there is any problem with the pneumatic system or
nozzles.
$660b A pneumatic error occurred during camera calibration. [EMER LEVEL]
[Problem]
Since the pneumatic system for the head does not operate or the pneumatic pressure is
lower than the norm (500 mmHg and above), the calibration cannot be performed.
[Solution]
error code “$660a”.
$660d The pneumatic pressure of Head $H is too high for the Z offset measurement. Check
the filter of the pneumatic system for clogging. [FREEZE LEVEL]
[Problem]
The pneumatic pressure of the nozzle before measurement exceeds the reference
(600Hg) when measuring the Z axis offset with the CN040 nozzle inserted in the
nozzle holder of the head or when measuring the Z axis position of the feeder, flux
unit, etc. automatically.
[Solution]
Check the nozzle for contamination and pneumatic pressure.
When the nozzle has no problem, check the filter of the head and clean it.
1-113
System Messages of the MMI and Solutions
If the problem occurs continuously, contact our designated C/S or local agent.
$7000 Component alignment method not supported by this equipment. [EMER LEVEL]
[Problem]
The component alignment method that was not defined was setup.
[Solution]
Click the <Edit> button after selecting the error occurred component in ‘Part’ of the
“PCB Edit” menu.
1-114
Advanced Chip Shooter DECAN S2 Troubleshooting Guide
1.4.11. Vision related errors in VME [$a000~$afff]
$a100 Error occurred during the processing of vision fiducial mark. [FREEZE LEVEL]
[Problem]
Vision fiducial mark sensing error occurred.
[Solution]
Turn off the Buzzer by pressing the “STOP” button.
Switch the machine to “IDLE” mode by pressing the “RESET” button.
Press the “READY” button to supply power to the machine.
Check and edit the data related to the corresponding fiducial mark setup after clicking
the ‘Fiducial Mark …’ button on the ‘board’ dialog box of PCB edit menu. Please
refer to section “6.3 Fiducial Mark Setup” of Administrator’s Guide for more
information.
$a131 Failed to recognize the vision fiducial mark of the first PCB. [FREEZE LEVEL]
$a132 Failed to recognize the vision fiducial mark of the second PCB. [FREEZE LEVEL]
$a133 Failed to recognize the vision fiducial mark of the third PCB. [FREEZE LEVEL]
$a134 Failed to recognize the vision fiducial mark of the fourth PCB. [FREEZE LEVEL]
[Problem]
The first fiducial mark recognition error occurred.($a131)
The second fiducial mark recognition error occurred.($a132)
The third fiducial mark recognition error occurred.($a133)
The fourth fiducial mark recognition error occurred.($a134)