9 SITEST
9.1 Overview SITEST
SITEST is a program for testing the various functions of individual assemblies in the SIPLACE machines.
General SITEST functions
Functions for machine settings
Functions for setting the dynamics of the axes
Calibration functions
Mapping functions
You can execute these functions using SITEST. You will find information on how to do this and details
on the interfaces in this chapter, software instruction for SITEST and by using the online Help function
while working with SITEST. In addition, you will find a number of practical examples described in the
online Help system.
9.1.1 Starting/Terminating the Test Program
9.1.1.1 Starting
X In the station software, switch over to the operator level for service technicians. The SITEST button
will be activated.
X Click on the in the main menu of the SIPLACE user interface. SITEST will be started.
WARNING:
The SITEST test program may only be used by SIEMENS AG staff or specially trained customer
personnel. Improper use of this test program will result in severe damage to the machine and
will pose a hazard to the operating personnel.
ATTENTION:
SITEST is a special station SW tool, which gives you access to the machine data needed for
placement.
SITEST allows you to perform individual function tests which are used in normal operation, in
combination with other functions and security queries.
X Before you open the protective hoods and manually intervene in the system (e.g. moving the
gantry), always stop any continuous functions in the test SW.
ATTENTION: NEVER just switch the machine off!
Never just switch the machine off in SITEST. There will be machine-relevant data open for
alteration and you will not be able to judge which write actions are still being or have not yet been
performed in these files.
Furthermore, each SIPLACE machine with SW version 603 or higher has 2 Windows XP
systems (station computer and machine controller), which could be damaged.
X ALWAYS use the shutdown menu on the station user interface or in Windows XP
Programs
– SIPLACE - Shutdown ALL
.
SITEST
Overview SITEST Starting/Terminating the Test Program
Student Guide Advanced Level 1 SIPLACE D-Series
SITEST EN 05/2007
9-2
X The main view of the user interface of the test program will appear on the screen shortly afterwards.
9.1.1.2 Terminating the Program
There are three ways of properly terminating the test program, i.e. either
Via the
Mode
menu and the menu item Exit,
or via the
ESC
button or by proceeding as follows:
X In the main view, click on the .
9-1: Starting SITEST.
X Confirm this message with
YES
.
NOTE:
The
ESC
button is the only option which closes SITEST from every window.
NOTE:
If newly determined or edited machine data have not been saved yet, an appropriate message
will be displayed before exiting the program prompting you to save the data (see example
below).
X Click on
YES
to save the data and exit
SITEST or click on
No
if you do not want to
save the data. The following dialog will be
shown:
X Click on
YES
. SITEST will be closed.
SITEST
SITEST Overview 603 Overview SITEST
Student Guide Advanced Level 1 SIPLACE D-Series
EN 05/2007 SITEST
9-3
9.1.2 SITEST Overview 603
As you can see in the overview diagram, the calibration menus in the SITEST software are allocated to
the hardware components on which each is fitted or for which the function is used.