SITEST Calibration Calibration - General Sequence S tuden t Guide Advanced Level 1 SIPLACE D-Series SITEST EN 05/2007 9-8 9.2.1 Calibration - General Sequence 9-2: General sequence to calibrate the machine 9.2.2 Requirem…

100%1 / 200
SITEST
Overview of Settings and Calibration Work Calibration
Student Guide Advanced Level 1 SIPLACE D-Series
EN 05/2007 SITEST
9-7
9.2 Calibration
Tools and SITEST
Calibration tool – general –
Version III not transparent is for HF/X/D machines with C&P6/12 and Twin/P&P Head [03010565-01]
(Version II transparent is for S/F/HS machines [00316308-03], calibration nozzle 920)
(Version for SST23 at X machines with C&P20 head [03034148-xx])
Nozzles – general –
Type 956, 517, 518, nozzle for ZPC of D-axis TH [03008862-03]
(C&P20 head: 1235)
Setting gauge for S tables
Board for calibrating the PCB conveyor width
2D coplan - (ILD2200) - calibration tool
SITEST, version 602.xx or higher
DANGER: RISK OF INJURY!
The gantry may move during some of the following procedures.
Therefore, before you begin with any of these procedures make sure that you and everyone else
stay physically clear of the travel range of the gantries.
X Also, sure, that no objects are in the way.
NOTE:
Before you begin with the calibration, you must reference the heads and the gantries.
During calibration, unused gantries will automatically be moved to their parking position.
To completely calibrate the machine, go to
Calibrate machine...
and select the
Calibrating
the entire machine
menu. This provides all the required calibration functions.
SITEST
Calibration Calibration - General Sequence
Student Guide Advanced Level 1 SIPLACE D-Series
SITEST EN 05/2007
9-8
9.2.1 Calibration - General Sequence
9-2: General sequence to calibrate the machine
9.2.2 Requirements for Calibration of Nozzle Changers in the SIPLACE D Machines
X Start SITEST.
X by selecting the menu items
MAIN VIEW
,
Overall reference run
, to start the reference run for all
gantries and heads.
X Configure the nozzle changer and check the component levels.
Precondition for calibrate the nozzle changer
Each magazine in the NC must be configured with a nozzle type.
There should be no nozzle at segment 1 .
Each magazine must at least have a nozzle present and configured (1) in garage 1 .
SITEST
C&P Head Calibration
Student Guide Advanced Level 1 SIPLACE D-Series
EN 05/2007 SITEST
9-9
9.2.3 C&P Head
9-3: Sequence of C&P head calibration
NOTE:
When configuring the C&P12 (only), you can also set all magazines to "empty" and the head to
"full".