D-serie level 1 EN.pdf - 第84页
C&P6/12 Placement Heads Overview Overview of C&P6/1 2 Head Parts S tuden t Guide Advanced Level 1 SIPLACE D-Series C&P6/12 Placement Heads EN 05/2007 6-4 6-2: C&P12 head Legend - overview of parts 2 1. Fo…

C&P6/12 Placement Heads
Overview of C&P6/12 Head Parts Overview
Student Guide Advanced Level 1 SIPLACE D-Series
EN 05/2007 C&P6/12 Placement Heads
6-3
Star station 3
Reject cycle
Once the gantry has reached the X/Y reject coordinates, the valve positioning unit closes the vacuum
duct to the nozzle. Faulty components are separated from the nozzle with a short air blast of
compressed air and are discarded.
Star station 7
The component is optically centered.
Star station 9
Pickup cycle
The nozzle is rotated into the pickup position.
Placement cycle
The component is rotated into the placement position.
Star station 10
Position for removal and insertion of sleeves for maintenance
Between star station 11&12
Option for C&P12: the presence or height of the component is checked before placement.
6.1.4 Overview of C&P6/12 Head Parts
6-1: C&P12 head
Legend - overview of parts 1
1. Collect&Place head 12 (DLM3)
[03041228-xx] (shown)
Collect&Place head 6 (DLM3)
[03048341-xx] (not for D4)
2. Light barrier "Z Axis Up " (behind the cover)
[00347297-xx]
3. Valve positioning drive, placement circuit
[00368076-xx]
Valve positioning drive, reject circuit
[00368074-xx]
4. Z-axis toothed belt
[00334936-xx]
5. Z-axis drive / DLM2
[03038908-xx]
6. Intermediate distributor, digital (behind the
cover)
[00330648-xx]

C&P6/12 Placement Heads
Overview Overview of C&P6/12 Head Parts
Student Guide Advanced Level 1 SIPLACE D-Series
C&P6/12 Placement Heads EN 05/2007
6-4
6-2: C&P12 head
Legend - overview of parts 2
1. Forced air unit with electromagnetic valve
(version 02 – downwards compatibility)
[00367793-xx]
2. Silencer
[03003134-xx]
3. Turning station / DLM2
[00341780-xx]
4. Component camera 18x18
[03014449-xx]
Component camera 27 x 27
[03018637-xx]
5. Compressed air supply for forced air unit
6. Compressed air supply for vacuum generator
(holding circuit and pick/place)
7. Vacuum measurement board (under the
cover)
6-3: C&P12 head
Legend - overview of parts 3
1. Star fitted / DLM2
2. "Z-axis down" sensor
3. RSF digital encoder 12/DLM2
4. Circular guide (raceway), aligned to star drive
axis
5. Star drive axis, centered by head housing and
Z-axis claw

C&P6/12 Placement Heads
C&P Head Placement Construction Overview
Student Guide Advanced Level 1 SIPLACE D-Series
EN 05/2007 C&P6/12 Placement Heads
6-5
6.1.5 C&P Head Placement Construction
6.1.5.1 Hardware - New Features for C&P Head
The D4 does not have a Head Modularity function, as this machine is designed to succeed the HS, as a
fast placement machine for small components.
The placement heads on the D-series have the following common/different features:
6.1.5.2 Placement Head Differences Between DLM 2/1 and DLM3
Assembly D4 D3 D2 D1
C&P head types C&P12 C&P12 or 6 C&P12 or 6 C&P12 or 6
Star drive ‚C28’
03031187-01
New bearings / strengthened motor shaft / green heat-shrinkable sleeve for star axis
incremental encoder cable
Forced air unit 00367793-02 new version 02: with date printed on the e-valve
DP station 00341780-05 version 5, downwards compatibility
Valve positioning
drives
Version 2
Requirements Minimum 601.03 SP1 or A364 axis controller
Head modularity No Same as X machines Reconfig. set C&P12
head 00119860-01
Reconfig. set C&P6
head 00119861-01
Special features Component sensor fasteners for C&P12 with 130Ncm
Hardware - new features for C&P head
Assembly DLM 1/2 DLM 3
C&P head type C&P12 & 6 C&P12 or 6
Placement star drive
‚C28’ 03031187-01
New bearings / stronger motor shaft / green
heat-shrinkable sleeve for star axis
incremental encoder cable New machine
data for star axis
Placement star drive
‚C29’
Compatible fitting for DLM1 and 2
New forced air unit Downwards
compatibility
YES
DP station 00341780-05 version 5, downwards compatibility
Valve positioning
drive
Version with original cam disk DLM1 / new
cam disk DLM2
DLM2 cam disk and version 2
Requirements Minimum SC/MC 601.03 SP1 or A364 axis
controller
Special features Component sensor fasteners for C&P12 with 130Ncm
Placement head differences between DLM 2/1 and DLM3