D-serie level 1 EN.pdf - 第89页

C&P6/12 Placement Heads Service Work on C&P Head - Details Overview S tude nt Guide Advanced Level 1 SIPLACE D-Series EN 05/2 007 C&P6/12 Placement Heads 6-9 6.1.7 Service Work on C&P Head - Det ails Serv…

100%1 / 200
C&P6/12 Placement Heads
Overview Compressed Air Supply on C&P Head
Student Guide Advanced Level 1 SIPLACE D-Series
C&P6/12 Placement Heads EN 05/2007
6-8
6.1.6 Compressed Air Supply on C&P Head
The compressed air for D1/2 machines is distributed via an additional T-piece and small component sets
with pneumatic hoses to the two placement heads.
6.1.6.1 Vacuum Generator
6-5: Pneumatic distributor under the gantry head distributor
Legend
1. Input: Exhaust Venturi nozzle pneumatic hose
(PK12)
2. Input: 7-fold pneumatic hose (PK 5)
3. Silencer for exhaust (indicated in the diagram)
4. Compressed air outlet for pickup/placement
circuit and holding circuit
D1/2: to T distributor C&P/P&P head
D4: to C&P head
6-6: Vacuum generator
Legend
1. Holding circuit supply
2. Placement and pickup circuit with branching
for air blast supply
3. Vacuum measuring board
4. Exhaust from the vacuum generator to the
silencer in the compressed air distributor
C&P6/12 Placement Heads
Service Work on C&P Head - Details Overview
Student Guide Advanced Level 1 SIPLACE D-Series
EN 05/2007 C&P6/12 Placement Heads
6-9
6.1.7 Service Work on C&P Head - Details
Service work
Chapter "C&P6/12" of the service manual explains the service work in detail, in the following order:
Replacing the C&P6/12 head - D1 D2
Replacing the front part
Replacing the component camera
Replacing the intermediate distributor
Replacing the turning station
Replacing the valve positioning drive, placement circuit
Replacing the valve positioning drive, reject circuit
Replacing the "Z-axis up" light barrier
Replacing the Z-axis drive
Replacing the Z-axis toothed belt
Replacing the "Z-axis down" sensor
Replacing the complete Z-axis
Replacing the forced air unit
Replacing the silencer
Replacing the star
Adjusting the star to the magnetic neutral position of the star motor
Replacing the star drive
Replacing the RSF digital rotary encoder
Replacing the control board for the nozzle changer 6/12
Checking the cable routing (DLM3)
Settings
The chapter "Settings" of the service manual explains the settings for the C&P6/12 head in detail:
Boards on the C&P6/12
Overview of settings for C&P12 (DLM3)
Setting the star axis resolution
Digital rotary encoder for the DP axis
Z-axis belt tension
Setting the Z-axis top end stopper
Light barrier down
Determining the zero point correction for the C&P head star axis
Setting the valve positioning drives for the mechanical position
Air blast values
Other mechanical settings for the placement star
C&P6/12 Placement Heads
Overview Overview Air Blast Supply
Student Guide Advanced Level 1 SIPLACE D-Series
C&P6/12 Placement Heads EN 05/2007
6-10
6.1.8 Overview Air Blast Supply
6-7: General overview of the air blast function