Overview Power Supply Unit Assemblies S tude nt Guide Advanced Level 1 SIPLACE D-Series EN 05/2007 Overview 3-17 3.4.5 Power Supply Unit The main power supply u nit is mounted on a compact rack modu le and is located on …

100%1 / 200
Overview
Assemblies Pneumatic Unit
Student Guide Advanced Level 1 SIPLACE D-Series
Overview EN 05/2007
3-16
3.4.4 Pneumatic Unit
The pneumatic unit is a fixed installation inside the machine and is located to the right of the middle
section of the machine, behind a flap. The pneumatic unit includes all electrical connections for control/
regulation of the compressed air supply.
3.4.4.1 Compressed Air Distributor Block
The pneumatic unit is used to prepare and distribute the compressed air required in the machine.. The
pressure at the compressed air connection must be at least 5.5 bar.
The following pneumatic circuits are supplied with compressed air via the distributor block:
3-10: D3/D4 pneumatic unit as rack unit
Legend
1. Compressed air connection with main shutoff
valve and manometer
2. 4x connection for bulkcase feeder with
manometer, adjustable (2.5 bar), location 1-4
3. 4x connection for cutters, location 1 - 4 (5 bar)
2x connection for conveyor lifting table
4. 4x connection for nozzle changer (5 bar)
5. 4x connection for docking/undocking
changeover table (5 bar)
6. Electronic control valve with manometer for
regulated machine pressure 5.x bar.
7. 4x connection for gantries 1 - 4, vacuum
generation C&P head with shutoff valves
8. Compressed air filter
D4 D3 D2 D1
Gantries Vacuum
generation Placement
heads
5.1 +/-0.1 bar 5.1 +/-0.1 bar 5.1 +/-0.1 bar 5.1 +/-0.1 bar
Conveyor System 5.1 +/-0.1 bar 5.1 +/-0.1 bar 5.1 +/-0.1 bar 5.1 +/-0.1 bar
tape cutter 5.1 +/-0.1 bar 5.1 +/-0.1 bar 5.1 +/-0.1 bar 5.1 +/-0.1 bar
Nozzle Changer 5.1 +/-0.1 bar 5.1 +/-0.1 bar 2.5 +/-0.1 bar 2.5 +/-0.1 bar
Feed-in units 5.1 +/-0.1 bar 5.1 +/-0.1 bar 5.1 +/-0.1 bar 5.1 +/-0.1 bar
Bulkcase feeder Manually set 2.5
bar
Manually set 2.5
bar
Manually set 2.5
bar
Manually set 2.5
bar
Overview of compressed air supply
Overview
Power Supply Unit Assemblies
Student Guide Advanced Level 1 SIPLACE D-Series
EN 05/2007 Overview
3-17
3.4.5 Power Supply Unit
The main power supply unit is mounted on a compact rack module and is located on the left side of the
middle section. When viewed from the outside, only the red main power switch is visible.
A lockable door prevents access to the power supply.
3.4.5.1 Overview of Voltages in the Power Supply Unit
3-11: Power supply – right-hand side view (D4/D2/D1)
Legend
1 Transformer 1 7 Power supply A1 (24 V/40 A)
2 Secondary terminal strip with fuses (output
voltage T1)
8 Line filter Z1 (input voltage)
9 Front view (see following diagram)
3 Connector strip X2-X10, X12, X13 10 Inrush current limiter (behind the cable duct)
4 Terminal strip X1
5 Power fail board A3 11 Various rectifiers (V5) (VDC only in D4 machine)
6 Power supply A2 (5 V/6.3 A)
Overview
Assemblies Power Supply Unit
Student Guide Advanced Level 1 SIPLACE D-Series
Overview EN 05/2007
3-18
3-12: Power supply (front view)
Legend
1. F1: 3x 230 V AC
SZ1: main contactor
MS1: Motor protection switch
S1: main switch
2. F2: 220 V AC for 5 V power supply
F4: 3x 140 VAC X/Y axes
SZ2,SZ3, SZ23: auxiliary contactors U,V,W for
X/Y servos
3. F5: 150 V DC star axis servo
F6: 40 V DC Z/DP axis servo
F7: 40 V DC changeover table
F8: 40 V DC PCB handling (conveyor)
F9: 8 V DC changeover table (only in D4, due
to 4 changeover tables)
F10: 48 V DC Vision illumination
F11: 24 V DC terminal strip distributor 2/4
F12: 24 V DC Microbox PC (MC)/control "ON"
(K1)
F13: 24 V DC Box PC (SR)/axis unit 1/2
F14: 24 V DC conveyor control (TSP 301)/
monitors
Z2: discharge inductor
4. K1: protective contactor combination
Relay1: control ON - button
SZ4: control ON - software
FU: fuse 6.3 AT 220 VAC to GND
FV: fuse 6.3 AT 220 VAC to GND
FW: fuse 6.3 AT 220 VAC to GND
FBU: fuse 6.3 AT 220 VAC to GND
X1: feed in - terminal strip
BU1: service socket