SITEST Calibration Basics New Functions in SITEST S tuden t Guide Advanced Level 1 SIPLACE D-Series SITEST EN 05/2007 9-20 Legend 1. This is where the axis data (Z and star axes) can be written from the head EPROM to the…

100%1 / 200
SITEST
New Functions in SITEST Calibration Basics
Student Guide Advanced Level 1 SIPLACE D-Series
EN 05/2007 SITEST
9-19
Head Data
9-12: Head modularity - head data
Legend
1. Select and set the relevant head type for the head replacement.
2. Select and set the relevant camera type for the selected head type or head replacement.
3. Shows the data for the head installed. The current BIOS and application version, the head type and
the camera type of the installed head.
Axis Data
9-13: Head modularity - axis data
SITEST
Calibration Basics New Functions in SITEST
Student Guide Advanced Level 1 SIPLACE D-Series
SITEST EN 05/2007
9-20
Legend
1. This is where the axis data (Z and star axes) can be written from the head EPROM to the machine
data. You can also write the Z and star axis data from the machine data to the head EPROM.
Function
9-14: Head modularity - function
Legend
1. After the head has been replaced, this function enables you to calibrate this head directly in the head
modularity menu. Of course it is also possible to calibrate the other heads with this function. The new
head and other heads can also be calibrated with SITEST, at
Calibrate machine...
,
All heads and
cameras...
.
2. The same applies as in(1). After the head exchange you can directly do a head- mapping. The head
mapping function can be found at
Calibrate machine
,
Head Mapping
.
SITEST
New Functions in SITEST Room for Your Sketches and Notes
Student Guide Advanced Level 1 SIPLACE D-Series
EN 05/2007 SITEST
9-21