1OM-1003-007.pdf - 第129页
1.5 Interruption of Automatic Operation 1.5.1 Interruption of Automatic Operation with [CANCEL] Button T o discontinue the production due to wrong selection of the current pat- tern program or product P .C.B.’s, interrup…

When "CYCLE" is set as "Stop Mode" (*1), select the [STEP]
button (entitled "STOP") in the "Run Mode" tab sheet ("OPN.
MODE" submenu window).
1.4.3 Stop Operation by Selection of "Auto Stop Mode"
Stop the input machine.
After all P.C.B.’s on the system line are processed and discharged, the
input machine automatically stops running.
(a) This function works only when "Enable" is set in the "Auto
stop mode" text box of the "P.C.B. Transfer Mode Setup"
tab sheet. (Operation Procedure: [SYSTEM] Button on
Main Menu Bar Æ [SYS DATA] Button Æ "Auto Opera-
tion" Tab Æ "P.C.B. Transfer Mode Setup" Tab Sheet)
(b) When a machine of another brand is connected to the
system line, this function may not work.
1.4 Temporary Stop and Restart of Automatic Operation
0309-002 3-17 AIL01EOPP
Note
Note

1.5 Interruption of Automatic Operation
1.5.1 Interruption of Automatic Operation with [CANCEL] Button
To discontinue the production due to wrong selection of the current pat-
tern program or product P.C.B.’s, interrupt the automatic operation.
(1) Press the [STOP] button on the front operation panel.
Fig. 1C25 "Run Mode 1" Tab Sheet
(2) When the [CANCEL] button (*1, entitled "CANCEL RUN") is pressed
after the "Run Mode 1" tab ("OPN. MODE" submenu window), the
automatic operation is interrupted.
To continue the automatic operation after the interruption, re-
fer to "Step (8)" and the subsequent items in "3.1 [EMERGENCY
STOP] Switch Pressed" in "Section 4" for details.
1.5 Interruption of Automatic Operation
*1
0406-003 3-18 AIL01EOPP
Note

1.5.2 Interruption with [EMERGENCY STOP] Switch
Use the [EMERGENCY STOP] switch to immediately stop the machine
in an emergency.
An error alarm is issued and the LED of the [POWER ON] button illumi-
nates in red.
Fig. 1C26
Refer to "Section 4 Remedy of Simple Trouble" in "Volume 1"
for the procedures to reset the machine to the normal condition
from an emergency stop.
1.5 Interruption of Automatic Operation
0305-001 3-19 AIL01EOPP
Note