1.7 Shut-Down Operation 1.7.1 Shut-Down Procedure The following explains how to shut down the power to the machine. Be sure to log out from an operation window to open the "Login T ype Selection" window and go …

1.6 End of Automatic Operation
1.6.1 Stop of Automatic Operation
(1) Confirm that "CYCLE" (*1) is set as "Stop Mode".
(2) When the [ON] button (*3, entitled "STOP") is pressed, each device
returns to its stationary position after the machine has placed com-
ponents on the P.C.B.’s inside the machine.
The LED of the [START] button and the green lamp (tower light)
extinguish and the automatic operation stops.
Fig. 1C27
When "STEP" is set as "Stop Mode" (*1), select the [CYCLE]
button (*2, entitled "STOP") in the "Run Mode 1 (or Run Mode
2)" tab sheet. "CYCLE" is set as "Stop Mode" (*1).
1.6 End of Automatic Operation
*1
*3
*2
0406-003 3-20 AIL01EOPP
Note

1.7 Shut-Down Operation
1.7.1 Shut-Down Procedure
The following explains how to shut down the power to the machine.
Be sure to log out from an operation window to
open the "Login Type Selection" window and go
through the shutdown procedure by pressing the
[SHUT DOWN] button before turning off the
power to the machine.
• When the power is shut down at a window other
than the "Login Type Selection" window, the saved
data (the management data, various data on the
hard disk, etc.) may be deleted.
Operation Procedure
(1) Press the [Logout] button on the main menu bar.
Fig. 1C28
1.7 Shut-Down Operation
CAUTION
0412-002 3-21 AIL01EOPP

(2) The "Login Type Selection" window opens.
Fig. 1C29
(3) When the [SHUT DOWN] button is pressed in the "Login Type Se-
lection" window, the "SHUT DOWN" dialog box opens for the con-
firmation.
Fig. 1C30 "SHUT DOWN" Dialog Box for Confirmation
(4) When the [Yes(Y)] button is pressed, the power to the machine is
turned off.
When the [No(N)] button is pressed, the shut-down operation is