1OM-1003-007.pdf - 第90页

2.4.2 L and R Conveyor Sections Fig. 1A22 These conveyors are used to receive a P .C.B. from the input machine and transfer it to the place right before the X/Y table or carry the compo- nent-placed P .C.B. to the output…

100%1 / 151
2.4 Main Units
2.4.1 Feeder Carriages
Fig. 1A21
The carriages carry feeders for component supply.
The tape or bulk feeders can be installed on the feeder carriages. The
carriages move right and left to supply components.
Never operate the machine with the feeder carriage
covers being open.
The feeder carriages are moved at high speed by
means of a strong motor.
It is very dangerous for a person or a thing to come in
contact with the moving section.
Components should be loaded on the tape or bulk feeders.
Refer to the instruction manual of the tape or the bulk feeders
for details.
Those who wear an implanted pacemaker are not al-
lowed to work inside the carriage covers.
Strong magnets are used in the feeder carriage sec-
tions.
Therefore, the pacemaker may be affected by mag-
netism.
2.4 Main Units
Feeder
Feeder Carriage
WARNING
0412-002 1-26 AIL01EOPP
Note
DANGER
2.4.2 L and R Conveyor Sections
Fig. 1A22
These conveyors are used to receive a P.C.B. from the input machine
and transfer it to the place right before the X/Y table or carry the compo-
nent-placed P.C.B. to the output machine.
When the P.C.B. flow direction is "L Æ R" (P.C.B. flow from left to right),
the L conveyor receives a P.C.B. from the input machine and transfers
it to the place right before the X/Y table.
The R conveyor receives the component-placed P.C.B. from the X/Y
table and transfers it to the output machine.
When the P.C.B. flow direction is "R Æ L" (P.C.B. flow from right to left),
the R conveyor receives a P.C.B. from the input machine and transfers
it to the place right before the X/Y table.
The L conveyor receives the component-placed P.C.B. from the X/Y
table and transfers it to the output machine.
2.4 Main Units
L Conveyor
R Conveyo
r
0305-001 1-27 AIL01EOPP
2.4.3 P.C.B. Transfer Section
Fig. 1A23
The P.C.B. transfer section is equipped with a feed claw that pushes
and transfers the P.C.B. (the P.C.B. received from the input machine by
the L conveyor when the flow direction is "L Æ R") onto the X/Y table.
It is very dangerous for a person or a thing to come in
contact with the feed claw.
Special care is required during working with the front
safety door being open.
2.4 Main Units
0412-002 1-28 AIL01EOPP
Rotary Turret
L Conveyor
X/Y Table
P.C.B. Transfer Claw
CAUTION