1-108 Next Generation, Multi-Functional Plac er DECAN S1 Troubleshooting Guide [Solution]  Perform [Solution] in $6040. $6520 Can't put, no noz zle in the Head. [EMER LEVEL] [Problem]  Same error as $6020 occurred…

100%1 / 204
1-107
System Messages of the MMI and Solutions
Check the existence of nozzle for the corresponding head.
Press the “READY” button to supply power to the machine.
Although a nozzle is actually mounted on the corresponding head, if it is setup not to
have been mounted on the error occurred head in the dialog box of the ANC menu,
tick the ‘No real motion (Manual)’ and after selecting the error occurred head, select
the ANC hole where the nozzle is put on the head. Then set up the ANC once more by
clicking the <Pick> button.
$6070 No nozzle in the head. Can't get. [FREEZE LEVEL]
[Problem]
Mismatch of ANC hole center after nozzle get operation, or nozzle does not exist in
the head due to inadequate height setup.
Vision nozzle check has not performed properly.
[Solution]
Perform [Solution] in $6030.
$6080 Z axis couldn't move to the get position. [FREEZE LEVEL]
[Problem]
Errors occurred while moving down the Z-axis for the nozzle ‘Get’ operation.
[Solution]
Perform [Solution] in $6040.
$6090 Z axis couldn't move to a safe height after getting. [FREEZE LEVEL]
[Problem]
Errors occurred while moving up the Z-axis for the nozzle ‘Get’ operation.
1-108
Next Generation, Multi-Functional Placer DECAN S1 Troubleshooting Guide
[Solution]
Perform [Solution] in $6040.
$6520 Can't put, no nozzle in the Head. [EMER LEVEL]
[Problem]
Same error as $6020 occurred during manual operation.
[Solution]
Please refer to [Problem] and [Solution] in $6020.
$6530 Nozzle in the Head. Couldn't put. [EMER LEVEL]
[Problem]
Same error as $6030 occurred during manual operation.
[Solution]
Please refer to [Problem] and [Solution] in $6030.
$6560 Can't get, nozzle in the Head. [EMER LEVEL]
[Problem]
Same error as $6060 occurred during manual operation.
[Solution]
Please refer to [Problem] and [Solution] in $6060.
$6570 No nozzle in the Head. Couldn't get. [EMER LEVEL]
[Problem]
Same error as $6070 occurred during manual operation.
[Solution]
Please refer to [Problem] and [Solution] in $6070.
$6571 The type of nozzle on the head $H does not correspond to the set nozzle. [FREEZE
LEVEL]
[Problem]
The result of vision nozzle type check after replacement of the head nozzle shows that
the nozzle does not correspond to the set nozzle.
[Solution]
Check that the nozzle in use corresponds to the set nozzle.
Check the internal and external diameters of the nozzle from the ‘Device’ submenu of
the ‘System Setup’ menu.
If the problem occurs continuously, contact our designated C/S or local agent.
1-109
System Messages of the MMI and Solutions
$6572 Head $H nozzle type check error occurred. [FREEZE LEVEL]
[Problem]
An error occurred while checking the vision nozzle type after replacement of the
nozzle.
[Solution]
Check the illumination state of the fly camera.
If the problem occurs continuously, contact our designated C/S or local agent.
$6609 No nozzle exists on the head. [EMER LEVEL]
[Problem]
Error occurred since the CN040 nozzle is not registered for the No. 3 hole of the ANC
during Z offset calibration.
[Solution]
Turn off the Buzzer by pressing the “STOP” button.
Press the “RESET” button to change the operation mode to “IDLE”.
Clicking the <Nozzle Prepare> button in the Z Offset window will register the CN040
nozzle automatically.
Or execute the ‘ANC Manager’ dialog box to register the CN040 to the No. 2 hole of
the corresponding ANC.