DECAN_S1_Troubleshooting_Guide(Eng_Ver1.3)_Print_Web.pdf - 第177页

1-153 System Messages of the MMI and Solutions $ad06 When performing “AutoTeach”, the numb er of parameters is diffe rent from that of the lead group, and it cannot be one p arameter. [Problem]  An error occurred due to…

100%1 / 204
1-152
Next Generation, Multi-Functional Placer DECAN S1 Troubleshooting Guide
[Solution]
Perform [Solution] in $ab2b.
$ad01 Not a type of the component available for ‘Auto Teach’.
[Problem]
Tried on a type of the component to which the ‘Auto Teach’ function is not supported.
The “Auto Teach” supports CHIP-Rect, TR, TR2, BGA, SOP, SOP2, SOJ, SOJ2, QFP,
PLCC and FLIPCHIP only.
[Solution]
Register manually the components for which ‘Auto Teach’ is not supported.
$ad02 Tangential distance shall be zero for ‘Atuo Teach’.
[Problem]
The ‘Auto Teach’ function is not supported for the component whose tangential
distance is not zero.
[Solution]
Register manually when the tangential distance of the component is zero.
$ad03 The number of leads on one side shall be minimum four for ‘Auto Teach’.
[Problem]
The ‘Auto Teach’ function is not supported for the components having less than four
leads on each side.
[Solution]
Register manually for the components having less than four leads on each side.
$ad04 There shall be no gap when performing the ‘Auto Teach’.
[Problem]
The ‘Auto Teah’ function is not supported for the components having missing pins.
[Solution]
Register manually for the components having missing pins.
$ad05 Lead group on one side shall be one for ‘Auto Teach’.
[Problem]
The ‘Auto Teach’ function is not supported for the component having more than two
lead groups on one side.
[Solution]
Register manually the component having more than two lead groups on one side.
1-153
System Messages of the MMI and Solutions
$ad06 When performing “AutoTeach”, the number of parameters is different from that of
the lead group, and it cannot be one parameter.
[Problem]
An error occurred due to H/W problem or S/W problem.
[Solution]
Turn off power to the machine in the usual way. Wait 5 seconds, turn back on and
reboot the system.
$ad07 Can not find the end of foot of the(%d)th lead group when performing ‘Auto Teach’
$ad08 Can not find the beginning of the foot of the(%d)th lead group when performing
‘Auto Teach’.
[Problem]
Lighting setup is inadequate.
[Solution]
Select the error occurred component in “Part” of the “PCB Edit” menu and check that
illumination is correctly setup in the “Profile Editor”.
Set the background of the component to look dark, and the lead and foot to look bright.
$ad09 Can not find the boundary of foot and lead in the(%d)th lead group when performing
‘Auto Teach’.
[Problem]
The boundary between the lead and foot is not visible when performing the ‘Auto
Teach’.
Lighting setup is inadequate.
[Solution]
Select the error occurred component in “Part” of the “PCB Edit” menu and check that
illumination is correctly setup in the “Profile Editor”.
Set the lighting so that the boundary of lead and foot is visible.
$ad10 Did not find the beginning of lead in the (%d)th lead group.
[Problem]
Lighting setup is inadequate.
[Solution]
Select the error occurred component in “Part” of the “PCB Edit” menu and check that
illumination is correctly setup in the “Profile Editor”.
Set the background of the component to look dark, and the lead and foot to look bright.
1-154
Next Generation, Multi-Functional Placer DECAN S1 Troubleshooting Guide
$ad11 An error of different numbers for ascent edge (%d) and descent edge (%d) occurred
in the lead group %d during auto teaching.
[Problem]
An error occurred due to H/W problem or S/W problem.
[Solution]
Turn off power to the machine in the usual way. Wait 5 seconds, turn back on and
reboot the system.
$ad12 An error in which the height (or width) of a component equals 1 pixel occurred during
auto teaching.
[Problem]
An error occurred due to H/W problem or S/W problem.
[Solution]
Turn off power to the machine in the usual way. Wait 5 seconds, turn back on and
reboot the system.
$ad13 Failed in recognition because there is no bright pixel exceeding the threshold(%d)
value on the screen when performing ‘Auto Teach’.
[Problem]
Lighting is set up too dark.
[Solution]
Select the error occurred component in “Part” of the “PCB Edit” menu, and add clarity
to the shape of the component by changing the illumination setup in the “Profile
Editor”.
$ad14 The component is off the effective range when performing ‘Auto Teach’.
[Problem]
The component was so large that it covered the outline of the screen.
The component was picked being offset and extended toward the edge of the screen.
Foreign matter except for the component looked bright.
[Solution]
Register manually if the size of the component is too large.
If the component is picked being offset, Check through SMVision window to
determine the pickup position of the corresponding component in the Feeder of the
“PCB Edit” menu.
Remove foreign matter if it looks brighter than the component.