1-123 System Messages of the MMI and Solutions Check if the lead of component is bent. Perform [Solution] in $a610. $a621 Pitch(%d) recognized by lead group(%d) is smaller than the registered pitch(%d). [Problem] T…

1-122
Next Generation, Multi-Functional Placer DECAN S1 Troubleshooting Guide
[Solution]
Perform [Solution] in $a610.
$a614 Can not find the first lead (left side) of lower lead group.
[Problem]
Failed to recognize the right lead of upper lead group on the SMVision window while
recognizing components.
Perform [Solution] in $a610.
$a615 Can not find the last (right side) lead of the lower lead group.
[Problem]
Failed to recognize the right lead of upper lead group on the SMVision window while
recognizing components.
[Solution]
Perform [Solution] in $a610.
$a616 Can not find the first (upper side) lead of right lead group.-+
[Problem]
Failed to recognize the right lead of upper lead group on the SMVision window while
recognizing components.
[Solution]
Perform [Solution] in $a610.
$a617 Can not find the last (lower side) lead of the right lead group.
[Problem]
Failed to recognize the right lead of upper lead group on the SMVision window while
recognizing components.
[Solution]
Perform [Solution] in $a610.
$a620 Recognized pitch(%d) in the lead group(%d) is larger than registered pitch(%d).
[Problem]
The pitch recognized by the vision is larger than the registered pitch.
Lead of component is bent.
Input the pitch of component is incorrect.
Setup of lighting level is inadequate.
[Solution]

1-123
System Messages of the MMI and Solutions
Check if the lead of component is bent.
Perform [Solution] in $a610.
$a621 Pitch(%d) recognized by lead group(%d) is smaller than the registered pitch(%d).
[Problem]
The pitch recognized in the vision is smaller than the registered pitch.
The component lead is bent.
Input the pitch of component is incorrect.
Lighting level setup is inadequate.
[Solution]
Check if the lead of component is bent.
Perform [Solution] in $a610.
$a631 There is not a bright(%d) pixel on the first(left side)lead of upper lead group.
[Problem]
The lead was not recognized when recognizing the component lead.
Can not actually pickup the component.
Lighting level was setup too dark.
The component size is inputted incorrectly.
[Solution]
Check if the component was actually picked up.
Perform [Solution] in $a610.
$a632 There is not a bright pixel(%d) on the first(upper side) lead of left lead group.
[Problem]
$a632There is not a bright pixel(%d) on the first(upper side) lead of left lead group.
The component was not picked up actually.
Lighting level was setup too dark.
The component size was inputted incorrectly.
[Solution]
Check if the component was actually picked up.
Perform [Solution] in $a610.
$a633 There isn’t a bright(%d) pixel on the first(left side)lead of lower lead group.
[Problem]
The lead was not recognized when recognizing the component lead .

1-124
Next Generation, Multi-Functional Placer DECAN S1 Troubleshooting Guide
The component was not picked up actually.
Lighting level was setup too dark.
The component size was inputted incorrectly.
[Solution]
The component size was inputted incorrectly.
Perform [Solution] in $a610.
$a634 There isn’t bright(%d) pixel on the first(upper side)lead of right lead group.
[Problem]
The lead was not recognized when recognizing the component lead.
The component was not picked up actually.
Lighting level was setup too dark.
The component size was inputted incorrectly.
[Solution]
Check if the component was actually picked up.
Perform [Solution] in $a610.
$a635 There isn’t boundary(%d) at the first(left side) upper lead of lead group.
[Problem]
The lead was not recognized when recognizing lead of the component first.
The component was not picked up actually.
Lighting level was setup too dark or too bright.
The foreign matter is recognized as lead.
The component size was inputted incorrectly.
[Solution]
Check if the component is actually picked up.
If there is any foreign matter between nozzle and mirror or between leads, please
remove it. For the method to remove foreign matter from the nozzle, please refer to “
Checking and cleaning the nozzle” in the “Maintenance Handbook”.
Perform [Solution] in $a610.
$a636 There isn’t boundary at the first(upper side)lead of left lead group.
[Problem]
The lead was not recognized when recognizing lead of the component first.
The component was not picked up actually.
Lighting level was setup too dark or too bright.