1-25 System Messages of the MMI and Solutions 1.2.2. Part Placement Error Parts not picked up - Errors causing parts not to be picked up [Refer to Section 1.2.2.1] Cause Description Remark s Parts are blown (low vacuum…

1-24
Next Generation, Multi-Functional Placer DECAN S1 Troubleshooting Guide
E0211 The nozzle is contaminated
[Cause]
The nozzle is contaminated
[Measures]
Clean the nozzle periodically referring to the Maintenance Handbook.
E0212 The head reference mark was not recognized properly (only for SM 411/411F/431/ 471
models)
[Cause]
The head 'Ref' mark is contaminated.
[Measures]
Clean the head 'Ref' mark

1-25
System Messages of the MMI and Solutions
1.2.2. Part Placement Error
Parts not picked up - Errors causing parts not to be picked up [Refer to Section 1.2.2.1]
Cause Description
Remark
s
Parts are blown (low
vacuum)
A component of the head’s pneumatic
system is defective
E0300
User parameter setup error (part thickness,
illumination brightness, etc.)
E0301
Excessive fluctuation range of main
pneumatic pressure (4.5 Mpa ~5.5 Mpa)
E0302
In the case of certain model, parts are
blown
E0303
Defective head vacuum solenoid cable
connector
E0304
PCB clamp error E0305
Setup error of the solenoid valve for blow
(strong)
E0306
PCB warp A PCB warps up and down E0310
A part adheres to the
nozzle
Setup error of the solenoid valve for blow
(weak)
E0320
Fouled vacuum filter E0321
The head vacuum filter case was not
assembled properly or was damaged
E0322
Defective solenoid valve E0323
The spindle is clogged E0324
Vacuum leaks from the rotary joint E0325
The LED part pickup position is sticky E0326
A large amount of oil entered the vacuum
generator
E0327
Static electricity generated E0328
Foreign material was adsorbed at the
nozzle tip
E0329
Part is stuck in the
nozzle
Standard nozzle is not used E0340
A nozzle unsuitable to the part is used E0341

1-26
Next Generation, Multi-Functional Placer DECAN S1 Troubleshooting Guide
Part is placed abnormally - Abnormal placement error [Refer to Section21.2.2.2 ]
Placement Error
Detection of defective
part pickup failed
The vacuum sensor has a problem. E0150
Defective nozzle check sensor operation
(PIP part)
E0351
Defective side view camera recognition E0352
Defective PCB
sensor
E0360
Cause Description
Remark
s
Defective
placement
accuracy
Bent spindle E0400
Common data setup error E0401
Defective connection of Z-axis driving
system
E0402
The Z-axis motor driver has a problem E0403
The Z-axis LM guide is defective E0404
Distorted part
(placement offset
occurred)
.Calibration has not been performed for a
long period of time. Therefore, offset
occurred to the gantry
.Condition changed according to the site
environment
E0410
After a certain period of time, XY
coordinate distortion occurred in the gantry
working area.
E0411
X and Y limit setup error E0412
Front and rear fiducial camera offsets have
changed
E0413
Offset has changed by being pushed to the
Y-axis
E0414
camera offset has changed E0415
PCB jump E0416
Incorrect nozzle selection E0417
PartR application error E0419
Defective camera assembling E0420
Abnormal R axis driving system E0421