1-116 Next Generation, Multi-Functional Plac er DECAN S1 Troubleshooting Guide An error occurred while reco gnizing comp onents with the flyin g camera due to H/W problem or S/W problem. [Solution] Check the state of…

1-115
System Messages of the MMI and Solutions
Check if the corresponding ‘Camera No.’ is setup properly in the ‘Part’ of the PCB
Edit menu.
$a210 Recognition by the flying camera is not completed. [EMER LEVEL]
[Problem]

1-116
Next Generation, Multi-Functional Placer DECAN S1 Troubleshooting Guide
An error occurred while recognizing components with the flying camera due to H/W
problem or S/W problem.
[Solution]
Check the state of the flying camera, cable and vision board. If any problem occurs,
contact the C/S company designated by Hanwha Precision Machinery Co., Ltd. or the
local agent.
Calibrate camera calibration. Please refer to section “Camera Calibration” on the
“12.3.10 Head & Camera Calibration” of the ” Administrator’s Guide”.
In order to confirm if the component data is normal, select the error occurred
component in “Part” of the “PCB Edit” menu and check if the information contained
in the <Align Data> group is set up in the Profile Editor correctly.

1-117
System Messages of the MMI and Solutions
$a211 Previous vision command is not completed. [EMER LEVEL]
[Problem]
An error occurred while recognizing components with the flying camera due to H/W
problem or S/W problem.
[Solution]
Perform [Solution] in $a210.
$a212 ‘Time Out Error’ of the recognition by the flying camera.
[Problem]
The time for the flying camera to recognize the component exceeded 24.000 seconds.
[Solution]
Perform [Solution] in $a210.
$a213 ‘Time Out Error’ of the recognition by the flying camera.
[Problem]
An error occurred while recognizing components with the flying camera due to H/W
problem or S/W problem.
[Solution]
Perform [Solution] in $a210.
$a220 Recognition by the upward camera is not completed.
[Problem]