1-177 System Messages of the MMI and Solutions $e809 Failed to initialize the H/W. [EMER LEVEL] [Problem]  An error occurred during system initialization. [Solution]  Check if the MMI/R T version is correct.  This err…

100%1 / 204
1-176
Next Generation, Multi-Functional Placer DECAN S1 Troubleshooting Guide
Memo Please contact us if any other error messages are shown.
Refer to the picture below for the location of the chip card.
$e807 An error exists in the system data. [EMER LEVEL]
[Problem]
A system data error occurred while loading the system data.
[Solution]
This problem occurred due to incorrect system version of the MMI/RT.
Check if the MMI/RT version is correct.
If trouble continues to occur, please contact the C/S company designated by Hanwha
Precision Machinery Co., Ltd. or the local agent.
$e808 Failed to initialize the S/W. [EMER LEVEL]
[Problem]
An error occurred during system initialization.
[Solution]
Check if the MMI/RT version is correct.
This error may occur when the system data in the system directory is abnormal. The
files to be checked include ‘config_N.db’, ‘machine.cfg’, ‘system.stm’, ‘factory.stm’,
etc.
If trouble continues to occur, please contact the C/S company designated by Hanwha
Precision Machinery Co., Ltd. or the local agent.
1-177
System Messages of the MMI and Solutions
$e809 Failed to initialize the H/W. [EMER LEVEL]
[Problem]
An error occurred during system initialization.
[Solution]
Check if the MMI/RT version is correct.
This error may occur when the system data in the system directory is abnormal. The
files to be checked include ‘config_N.db’, ‘machine.cfg’, ‘system.stm’, ‘factory.stm’,
etc.
Check the system related to the control of the hardware with which a problem
occurred.
In the case of the vision hardware initialization error, turn the machine off normally
and turn it on again to check if it is initialized properly.
If trouble continues to occur, please contact the C/S company designated by Hanwha
Precision Machinery Co., Ltd. or the local agent.
1.4.16. Internal data related errors (Exception Error + OS Error) [$f000~$ffff]
$f800~$fb12An error occurred due to internal S/W problem. [MPU_STOP LEVEL]
[Problem]
Internal S/W problem.
[Solution]
Turn off power to the machine in the usual way. Wait 5 seconds, turn back on and
reboot the system.
$fb22 An object was detected by the front area sensor. [WARNING LEVEL]
$fb22 An object was detected by the rear area sensor. [WARNING LEVEL]
[Problem]
Object was detected by the front (rear) sensor in an unsafe situation.
[Solution]
Check the operation state of the safety sensor.
Remove the object detected by the safety sensor.
$ff00 Cannot start production. [WARNING LEVEL]
[Problem]
The machine driving motor was not homed.
In the case of the docking cart machine, an error occurs due to defective clamping,
vision communication error, etc.
1-178
Next Generation, Multi-Functional Placer DECAN S1 Troubleshooting Guide
[Solution]
Perform homing of the machine driving motor.
Clamp the docking cart properly.
Check the state of communication with the vision system by performing the functions
of Outline, Test, Pickup, etc. using the part information registered in the ‘Part Edit’
dialog box.
Despite such checks and measures, if the problem occurs again, contact our designated
C/S and local agent.