System Messages of the MMI and Solutions
The foreign matter is recognized as lead .
The component size was inputted incorrectly.
[Solution]
Perform [Solution] in $a635.
$a637 There isn’t boundary(%d) at the first(left side)lead of lower lead group.
[Problem]
The lead was not recognized when recognizing lead of the component first.
The component was not picked up actually.
Lighting level was setup too dark or too bright.
The foreign matter is recognized as lead.
The component size was inputted incorrectly.
[Solution]
Perform [Solution] in $a635.
$a638 There isn’t boundary(%d) at the first(upper side)lead of right lead group.
[Problem]
The lead was not recognized when recognizing lead of the component first.
The component was not picked up actually.
Lighting level was setup too dark or too bright.
The foreign matter is recognized as lead.
The component size was inputted incorrectly.
[Solution]
Perform [Solution[Solution]] in $a635.
$a641 There is a bright pixel outside the first(left side) lead of upper lead group.
[Problem]
The lead of component was recognized, but other thing was recognized outside of the
lead.
The mirror is contaminated with foreign matter.
The nozzle is contaminated with foreign matter or its coating was peeled off.
Component data and lighting is inadequate.
[Solution]
Perform [Solution] in $a635.
1-126
Next Generation, Multi-Functional Placer DECAN S1 Troubleshooting Guide
$a642 There is bright pixel at the first(upper side) lead of left lead group.
[Problem]
The lead of component was recognized, but other thing was recognized outside of the
lead.
The mirror is contaminated with foreign matter.
The nozzle is contaminated with foreign matter or its coating was peeled off.
Component data and lighting is inadequate.
[Solution]
Perform [Solution] in $a635.
$a643 There is bright pixel outside of the first(left side) lead of lower lead group.
[Problem]
The lead of component was recognized, but other thing was recognized outside of the
lead.
The mirror is contaminated with foreign matter.
he nozzle is contaminated with foreign matter or its coating was peeled off.
Component data and lighting is inadequate.
[Solution]
Perform [Solution] in $a635..
$a644 There is bright pixel outside of the first(left side) lead of lower lead group.
[Problem]
The lead of component was recognized, but other thing was recognized outside of the
lead.
The mirror is contaminated with foreign matter.
he nozzle is contaminated with foreign matter or its coating was peeled off.
Component data and lighting is inadequate.
[Solution]
Perform [Solution] in $a635.
$a645 Boundary at the first(left side) lead of upper lead group is small.
[Problem]
Length of the component lead is recognized too short.
Lead of the component is actually defective.
False recognition of foreign matter as lead.
The component data and lighting setup is inadequate.
1-127
System Messages of the MMI and Solutions
[Solution]
The component data and lighting setup is inadequate.
Perform [Solution] in $a635.
$a646 Boundary at the first(upper side) lead of left side lead group is small.
[Problem]
Length of the component lead is recognized too short.
Lead of the component is defective.
False recognition of foreign matter as lead.
False recognition of foreign matter as lead.
[Solution]
Check if the lead is defective.
Perform [Solution] in $a635.
$a647 Boundary at the first(left side) lead of the lower lead group is small.
[Problem]
Length of the component lead is recognized too short.
Lead of component is defective.
False recognition of foreign matter as lead.
Component data and lighting setup is inadequate.
[Solution]
Check if the lead is defective.
Perform [Solution] in $a635.
$a648 Boundary at the first(upper side) lead of right side lead group is small.
[Problem]
Length of the component lead is recognized too short.
Lead of the component is defective.
False recognition of foreign matter as lead.
The component data and lighting setup is inadequate.
[Solution]
Check if the lead is defective.
Perform [Solution] in $a635.
$a649 First(left side) lead of upper lead group is a not straight line.
[Problem]