DECAN_S1_Troubleshooting_Guide(Eng_Ver1.3)_Print_Web.pdf - 第156页
1-132 Next Generation, Multi-Functional Plac er DECAN S1 Troubleshooting Guide $a712 <WARNING> Can not find the first(upp er side)lead of left side lead group. [Problem] <W ARNING> Can not find the first(up…

1-131
System Messages of the MMI and Solutions
Incorrect registration the number of leads in the component data
The component data and lighting setup is inadequate.
[Solution]
Check if the component lead is defective.
Perform [Solution] in $a610.
$a672 Failure to locate the end pin of the left lead group.
[Problem]
Failed in detailed recognition of component lead.
The component lead is defective.
Incorrect registration the number of leads in the component data.
The component data and lighting setup is inadequate.
[Solution]
Check if the component lead is defective.
Perform [Solution] in $a610.
$a673 Failure to locate the end pin of the lower lead group.
[Problem]
Failed in detailed recognition of component lead.
The component lead is defective
Incorrect registration the number of leads in the component data.
The component data and lighting setup is inadequate.
[Solution]
Check if the component lead is actually defective.
Perform [Solution] in $a610.
$a674 Failure to locate the end pin of the right lead group.
[Problem]
Failed in detailed recognition of component lead.
The component lead is defective.
Incorrect registration the number of leads in the component data.
The component data and lighting setup is inadequate.
[Solution]
Check if the component lead is actually defective.
Perform [Solution] in $a610.

1-132
Next Generation, Multi-Functional Placer DECAN S1 Troubleshooting Guide
$a712 <WARNING> Can not find the first(upper side)lead of left side lead group.
[Problem]
<WARNING> Can not find the first(upper side)lead of left side lead group.
[Solution]
Turn off power to the machine in the usual way. Wait 5 seconds, turn back on and
reboot the system.
$a723 <WARNING> Can not find the first(left side) lead of lower lead group.
[Problem]
<WARNING> Can not find the first(left side) lead of lower lead group.
[Solution]
Turn off power to the machine in the usual way. Wait 5 seconds, turn back on and
reboot the system.
$a811 Can not calculate the angle of component while recognizing component.
[Problem]
The shape of component is circular.
The angle cannot be calculated due to hardware or software problem.
[Solution]
When the shape of component is circular, register the component as ‘CHIP-Circle’
type.
$a822 Width (X value) of the component does not match with the registered value.
[Problem]
Occurs when there is big difference between the recognized component width and
registered value.
Defective component.
The component data and lighting setup is inadequate.
[Solution]
Check if the component is defective.
Perform [Solution] in $a610.
$a823 Height of the component(Y value) does not match with the registered value.
[Problem]
Occurs when there is big difference between the recognized component width and
registered value.
Defective component.

1-133
System Messages of the MMI and Solutions
The component data and lighting setup is inadequate.
[Solution]
Check if the component is defective.
Perform [Solution] in $a610.
$a824 Center of the component is deviating too much from the nozzle center in X direction.
[Problem]
The component is recognized, but it is too much offset.
Pickup position or pickup condition of the component is inadequate.
[Solution]
Check through SMVision window to determine the pickup position of the
corresponding component in the Feeder of the “PCB Edit” menu.
$a825 Center of the component is deviating too much from the nozzle center in X direction.
[Problem]
The component is recognized, but it is too much offset.
Pickup position or pickup condition of the component is inadequate.
[Solution]
Check through SMVision window to determine the pickup position of the
corresponding component in the Feeder of the “PCB Edit” menu.
$a826 Angle of the component is too wide.
[Problem]
Recognized angle of the component exceeds the registered range.
Rotated too much during pickup of the component.
[Solution]
Check through SMVision window to determine the pickup position of the
corresponding component in the Feeder of the “PCB Edit” menu.
$a830 No object is visible in the retrieve range.
[Problem]
The component was not actually picked up.
Lighting is too dark.
[Solution]
Check if the component has actually picked up.
Select the error occurred component in “Part” of the “PCB Edit” menu and check the