DECAN_S1_Troubleshooting_Guide(Eng_Ver1.3)_Print_Web.pdf - 第155页

1-131 System Messages of the MMI and Solutions  Incorrect registration the number of leads in the component data  The componen t data and lighting setu p is inadequate. [Solution]  Check if the component lead is defec…

100%1 / 204
1-130
Next Generation, Multi-Functional Placer DECAN S1 Troubleshooting Guide
$a654 There isn’t bright(%d) pixel at the final(upper side)lead of right side lead group.
[Problem]
Position of component lead looks black.
The component lead is actually defective.
Mirror is the contaminated with foreign matter.
There is foreign matter on the nozzle or nozzle coating is peeled off.
The component data and lighting setup is inadequate.
[Solution]
Check if the component lead is actually defective.
Perform [Solution] in $a635.
$a660 Can not find any lead while recognizing %d direction lead group(%d).
[Problem]
There is no lead in the lead group recognition range.
The component is defective in size.
The component data or lighting setup is inadequate.
[Solution]
Check if the component size is actually defective.
Perform [Solution] in $a610.
$a665 Recognized number(%d) of lead of %d direction lead group(%c) is different from the
registered number of lead(%d).
[Problem]
Registered number of leads for the component is different from the recognized number
of leads.
The component lead is defective.
Incorrect registration the number of leads in the component data.
The component data and lighting setup is inadequate.
[Solution]
The component data and lighting setup is inadequate.
Perform [Solution] in $a610.
$a671 Failure to locate the end pin of the upper lead group.
[Problem]
Failed in detailed recognition of component lead.
Failed in detailed recognition of component lead.
1-131
System Messages of the MMI and Solutions
Incorrect registration the number of leads in the component data
The component data and lighting setup is inadequate.
[Solution]
Check if the component lead is defective.
Perform [Solution] in $a610.
$a672 Failure to locate the end pin of the left lead group.
[Problem]
Failed in detailed recognition of component lead.
The component lead is defective.
Incorrect registration the number of leads in the component data.
The component data and lighting setup is inadequate.
[Solution]
Check if the component lead is defective.
Perform [Solution] in $a610.
$a673 Failure to locate the end pin of the lower lead group.
[Problem]
Failed in detailed recognition of component lead.
The component lead is defective
Incorrect registration the number of leads in the component data.
The component data and lighting setup is inadequate.
[Solution]
Check if the component lead is actually defective.
Perform [Solution] in $a610.
$a674 Failure to locate the end pin of the right lead group.
[Problem]
Failed in detailed recognition of component lead.
The component lead is defective.
Incorrect registration the number of leads in the component data.
The component data and lighting setup is inadequate.
[Solution]
Check if the component lead is actually defective.
Perform [Solution] in $a610.
1-132
Next Generation, Multi-Functional Placer DECAN S1 Troubleshooting Guide
$a712 <WARNING> Can not find the first(upper side)lead of left side lead group.
[Problem]
<WARNING> Can not find the first(upper side)lead of left side lead group.
[Solution]
Turn off power to the machine in the usual way. Wait 5 seconds, turn back on and
reboot the system.
$a723 <WARNING> Can not find the first(left side) lead of lower lead group.
[Problem]
<WARNING> Can not find the first(left side) lead of lower lead group.
[Solution]
Turn off power to the machine in the usual way. Wait 5 seconds, turn back on and
reboot the system.
$a811 Can not calculate the angle of component while recognizing component.
[Problem]
The shape of component is circular.
The angle cannot be calculated due to hardware or software problem.
[Solution]
When the shape of component is circular, register the component as ‘CHIP-Circle’
type.
$a822 Width (X value) of the component does not match with the registered value.
[Problem]
Occurs when there is big difference between the recognized component width and
registered value.
Defective component.
The component data and lighting setup is inadequate.
[Solution]
Check if the component is defective.
Perform [Solution] in $a610.
$a823 Height of the component(Y value) does not match with the registered value.
[Problem]
Occurs when there is big difference between the recognized component width and
registered value.
Defective component.