1-34 Next Generation, Multi-Functional Plac er DECAN S1 Troubleshooting Guide Check the AMP parameter . Check whethe r noise is heard while the machine is stopped, JOG and oper ation. If so, contact our designated C/…

1-33
System Messages of the MMI and Solutions
E0360 The PCB was bypassed without being worked on due to the defective PCB detection
sensor
[Cause]
The PCB sensor is defective.
[Measures]
Contact our designated C/S company or local agent. (Replace the sensor)
1.2.2.2. Abnormal Placement Error
E0400 The XY coordinates of the corresponding spindle center become incorrect due to a
deformed ball spline
[Cause]
The ball spline is warped
[Measures]
Contact our designated C/S company or local agent. (Replace the ball spline)
E0401 Incorrect common data setup
[Cause]
1) Incorrect setup of vacuum/blow delay time
2) Incorrect part transfer speed setup
[Measures]
1) Set the delay time suitable for the part to be placed while changing the vacuum/blow
delay time little by little.
2) Set the speed suitable for the part to be placed while changing the part transfer speed
little by little.
E0402 The Z-axis driving system was not connected properly
[Cause]
Defective motor or belt connection
[Measures]
Contact our designated C/S company or local agent. (Check the driving motor and belt
for any defect)
E0403 The Z-axis motor driver does not operate properly
[Cause]
Incorrect gain or properties of the motor were inputted.
[Measures]

1-34
Next Generation, Multi-Functional Placer DECAN S1 Troubleshooting Guide
Check the AMP parameter.
Check whether noise is heard while the machine is stopped, JOG and operation. If so,
contact our designated C/S company or local agent. (Download the corresponding
parameters or change specific parameters again).
E0404 The Z axis LM guide is defective
[Cause]
The LM Guide is defective
[Measures]
Contact our designated C/S company or local agent. (Replace the ball spline)
E0410 Gantry offset occurred since calibration has not been performed for a long period of
time
[Cause]
Calibration has not been performed for a long period of time. (Condition change
according to the site environment)
[Measures]
Perform the common XY calibration referring to the Administrator's Guide.
E0411 After a certain period of time, XY coordinate distortion occurred in the working area
of a certain gantry.
[Cause]
Gantry mapping was performed incorrectly due to a defective fiducial mark position
for the temperature mapping of a certain gantry.
[Measures]
Check whether the fiducial mark position for temperature mapping is correct and
perform temperature mapping again.
E0412 Incorrect X and Y limit setup
[Cause]
Incorrect X and Y limit setup
[Measures]
Perform the axis calibration referring to the Administrator's Guide.
E0413 The offsets of the front/rear fiducial cameras were changed
[Cause]
The offsets of the front/rear fiducial cameras occurred
[Measures]

1-35
System Messages of the MMI and Solutions
Perform the fiducial camera offset calibration referring to the Administrator's Guide.
E0414 The offset was changed since it was pushed to the Y-axis
[Cause]
The offset was changed since it was pushed to the Y-axis
[Measures]
Calibrate the placement accuracy using the mounter offset
E0415 The camera offset has been changed
[Cause]
The offset of the flying camera or fix camera occurred
[Measures]
Perform calibration of the head and camera referring to the Administrator's Guide.
E0416 The PCB jumps up while placing parts on it
[Cause]
1) Incorrect setup of the backup pin
2) Incorrect setup of the BUT Down speed
[Measures]
1) Check whether there is a clearance between the board and clamp plate in the Clamp
Up state and adjust the backup pin length.
2) Check the BUT lowering down time at the Conveyor Module Diagnosis and control
the speed control valve so that the lowering time may not exceed 150-170 ms.
E0417 A nozzle not suitable to the part was used
[Cause]
A nozzle not suitable to the part was used
[Measures]
Change the nozzle with the one suitable for the corresponding work referring to the
Operation Handbook.
E0419 Incorrect application of PartR
[Cause]
Incorrect placement angle
[Measures]
Apply the PartR suitable for the corresponding part.