L&A INSTALLATION MANUAL LINE COMPUTER LCL 503.04
NSTALLING THE LINE COMPUTER SOFTWARE INUX U
I
LRL L (S SE 9.0)
in the event of an upgrade, proceed with section 4.2.4 Update: Installation via «Install Op-
tions»
in the event of a pure LCL installation, proceed with section 4.2.5 Installation entries of LCL
software installation
4.2.2 New installation
The following remarks should be considered during a new installation.
4.2.2.1 Econel 30
NOTE
When using an «Econel 30» system (these have both a DVD and a CD wri-
ter) the installation CD must be inserted into the CD writer drive!
4.2.2.2 Econel 40
Before starting the installation of «auteq Linux 9.0» onto an «Econel 40», you have to check and
maybe change the BIOS settings:
1. After switch on the computer, press the ‹Delete› key, to enter the setup.
2. Select the 2
nd
page «Advanced»
3. Select the menu entry «IDE-Configuration»
4. Change the setting S-ATA Mode [Native]
to S-ATA Mode [Legacy]
e.g. using the ⊕ key.
Now you can start the installation as described below. If you don’t change the BIOS settings, the in-
stallation will abort with the message:
Error:
No hard disks were found for the installation.
Please check your hardware!
OK
L&A EA SUBJECT TO CHANGE WITHOUT PRIOR NOTICE 03.03.2005
RUPERT-MAYER-STR. 44
D-81359 M
UNICH SWIA_503.04_EN.DOC PAGE 10 / 75

L&A INSTALLATION MANUAL LINE COMPUTER LCL 503.04
NSTALLING THE LINE COMPUTER SOFTWARE INUX U
I
LRL L (S SE 9.0)
4.2.2.3 Econel 50
Additional driver floppies are required when installing an «Econel 50» computer (order number
03037356-1 –SIPLACE Compact Server 4) with SuSE Linux 9.0 and LCL 503.04:
for controlling the SATA RAID controllers
(order number 00377053-01 Disc SATA RAID – SuSE 9.0 – Econel 50)
for the network card
(order number 00377054-01 Disc NETWORK CHIP SET – SuSE 9.0 – Econel 50)
For the «Econel 50» you need also the additional CD for Service Pack 1
(order number 00376174-02 CD LINUX 503.04 – Service Pack 1 – Econel 50)
The complete package can be ordered under the number 00377052-01 (Patch LINUX SuSE 9.0 –
Econel 50).
Cause:
The «Econel 50» should be used with the SATA controller.
A new type of network card is used in the «Econel 50».
WARNING
Using an «Econel 50» with linecomputer software LCL 503.04 and Service
Pack 1, you have to use the special CD «CD LINUX 503.04 – Service Pack
1 – Econel 50».
You must not use the former installation CD for the Service Pack 1 (version
01)!
4.2.2.4 19” Monitor
NOTE
If you want to install a system, using a «19” monitor» (flat screen), at first,
you have to change the resolution of the monitor onto the value 1024x768
(see step 1 below on page 12)
4.2.2.5 Replace filesystem «ReiserFS» by «Ext3»
The «Reiser filesystem» under «auteq Linux 9.0» is not as error-tolerant as expected.
If the computer is not shut down correctly, but simply switched off, any files still open at that time are
not corrected properly when the system is rebooted and can thus no longer be read or written to.
Regrettably it’s not possible to change the filesytem type on an installed system. But during a new
installation, you should use the opportunity to change from the preset filesystem «ReiserFS» to the
filesystem «Ext3».
L&A EA SUBJECT TO CHANGE WITHOUT PRIOR NOTICE 03.03.2005
RUPERT-MAYER-STR. 44
D-81359 M
UNICH SWIA_503.04_EN.DOC PAGE 11 / 75

L&A INSTALLATION MANUAL LINE COMPUTER LCL 503.04
NSTALLING THE LINE COMPUTER SOFTWARE INUX U
I
LRL L (S SE 9.0)
4.2.3 Installation Manual «new installation»
Switch the computer on and insert the installation CD, if you haven't already done so. This is
necessary in order to install from CD ROM
4.2.3.1 Installation with 19” Monitor
1. If you use an 19” Monitor (flat screen) for the installation, consider step 2 below. Otherwise con-
tinue at step 3 below.
2. On systems, using the 19” monitor, the resolution must be changed to the value of 1024x768
before starting the installtion. Press ‹F2› key on the start screen to change the resolution, then
continue the installation as normal.
HINT
After the installtion had been finished, you could use the configuration tool
«YaST2» to change the resolution to 1280x1024. But since the line com-
puter application is designed for the resolution 1024x768, not the whole dis-
play will be used.
4.2.3.2 Installation of Econel 50
3. Performing the new installation on a system «Econel 50», you have to follow the steps at 4 be-
low.
For older systems until «Econel 40», continue at step 14 below on page 15.
L&A EA SUBJECT TO CHANGE WITHOUT PRIOR NOTICE 03.03.2005
RUPERT-MAYER-STR. 44
D-81359 M
UNICH SWIA_503.04_EN.DOC PAGE 12 / 75