00198000-02_VD_709.1_DE_EN.pdf - 第35页
Station Software 709.1 / Version Descript ion Ausgabe 05/2016 E dition 35 7 Restrictions X- Feeder Because of the m irrored gantry configuration, the number of the ava ilable tracks o n gantry 2 and 4 on the X4 i , X4i S…

Station Software 709.1 / Version Description Ausgabe 05/2016 Edition
34
6.4 SIPLACE Traceability Version 5.1
Software version 5.1 of SIPLACE Traceability supports the SIPLACE X-series, X-series S,
SX-series, DX-series, CA-series and TX-series placement machines.
Compatible mode: SIPLACE Traceability 4.x
NOTICE
A detailed description can be found in the "Traceability User Guide".
Station Software 709.1 / Version Description Ausgabe 05/2016 Edition
35
7 Restrictions
X-Feeder
Because of the mirrored gantry configuration, the number of the available tracks on gantry 2 and 4
on the X4i, X4i S, SX4 and DX4 placement machines are restricted, not all of the tracks can be
reached by the placement heads. Feeders set on non-reachable tracks are deactivated
automatically.
Number of nozzle changer magazines
Because of the mirrored gantry configuration, the number of configurable nozzle changer
magazines on gantry 2 and 4 on the X4i, SX4 and DX4 placement machines is limited to 4
magazines.
Fiducial patterns
Asymmetric fiducial patterns (e.g. triangles) can currently only be used if the board is processed at
an orientation of 0° in the machine.
X-table
An additional table fiducial is necessary for the gantries 2 and 4 on the X4i and SX4 placement
machines.
Twin Head/HFH
– Twin Head/HFH are not supported on the X4i and DX4 placement machines.
– Not vacuum pump compatible.
– Not all pickup, dip and placement positions are accessible for both segments on the SX1/SX2
and SX4 placement machines.
CPP placement head
– Restrictions for the X2, X3, X4, X4i and SX4 placement machines can be found in the
correspondent User Guides to the X-series and in the Version Description to SIPLACE Pro.
– Not vacuum pump compatible.
– Not supported on DX series placement machines.
VHF P&P placement head
Supported on the SX1/SX2 V2 placement machine only.
Reduced air consumption with vacuum pump
No support for Twin Head and CPP placement heads.
Automatic tray feeding
The function is not supported on the X4i, SX4 and DX4 placement machines.
Station Software 709.1 / Version Description Ausgabe 05/2016 Edition
36
Dip module LDU_X
– Parameterization in the component shape is not transferred to the LDU_X module. The
parameters have to be additionally set at the LDU_X module.
– Reduced LDU_X performance, as maximum 2 A can be provided for each feeder. Therefore
the drives of the LDU_X module cannot reach the maximum possible acceleration.
– LDU_X modules cannot be placed on any track of the X-table because of restrictions
concerning the accessibility with the twin head. The range of usable tracks for setting up
LDU_X modules is limited in SIPLACE Pro.
– LDU_X module and manual tray cannot be placed together on one table on the machine types
X2, X3, X4, X4i and SX4.
– The eSW of the LDU_X module can only be updated via notebook and serial interface.
– Maximum component dimension: 45 x 45 mm. For TwinHead: squeegee cycle between the two
dipping processes, if the components on both head segments have to be dipped.
– Setup verification is not supported with the LDU-X module.
– Reachability of the LDU_X module in the X-, SX- and DX-series:
X2: location 1 and 3 39.5 mm
location 2 and 4 54 mm
X3: location 1 22.5 mm
location 3 39.5 mm
location 2 and 4 54 mm
X4: location 1 and 3 C&P20/CPP, 38 mm
location 2 und 4 no restriction
X4i: All locations 38 mm of 75 mm
SX1/2 and DX1/2:
location 1 or 2 inner position: no restriction
outer position: half of the dipping area
SX4 All locations 38 mm of 75 mm
– Dipping with the C&P20A placement head is only possible with LDU_X as of function version 3.
Fast head exchange
– The function only supports the C&P20A and CPP placement heads.
– Stationary cameras will always be calibrated.
– A placement head should always be replaced by a placement head of the same type. If a
placement head is replaced by another head type, the fast exchange time is not granted, as
configuration changes, setup change and hardware exchange will follow.
– A manual head exchange is not detected (e.g. if a placement head is manually disassembled
and identically reassembled during maintenance).
Virtual PCB stack
– The boards will only be placed if the corresponding "PCB Detection Inkspots" is detected.
– No plausibility check is performed. I.e., if both inkspots are detected by mistake, both board
contents will be placed. If neither of the two inkspots is detected, no placement will be
performed.