00198000-02_VD_709.1_DE_EN.pdf - 第49页
Station Software 709.1 / Version Descript ion Ausgabe 05/2016 E dition 49 D1 - 119185512 The gantry could not be moved when a h igh compone nt which covers the component sens or should be placed. D1 - 119215101 eSW: erro…

Station Software 709.1 / Version Description Ausgabe 05/2016 Edition
48
D1-121699901
D1-121459201
If a feeder with pitch setting "0" (no information) was removed and inserted
again a wrong pitch value (<>0) was loaded.
D1-122294801 Message: 37800 Machine stopped due to too many repetitive
errors on segment 2
.
D1-122349801 The export of the GUI activity levels did not work if a password had been set.
D17936-759 In case of a track error (e.g. run out of components) and trying to omit this
component, all feeders of the table were listed and all could be selected.
D18055-2411 The automatic calibration of heads and cameras function did not work if
Coplan should be calibrated.
Table 8-2: Corrected errors 709.0 Hotfix 3
709.0 Hotfix 2
Error no. Error description
D1-114416401 The machine stopped without error message when the height of the tray was
not correct.
D1-115338699 Automatic pitch detection was executed for a 4 mm feeder although the
detection was not activated for this feeder type.
D1-117279506 The machine was searching for a fiducial in the wrong place.
D1-118060197 When the job changes, the support pins were not automatically returned to the
magazine.
D1-118158001 The pocket recognition failed during the auto pitch detection.
D1-118183801 Reference run for DLM4 head was sporadically not possible.
It worked again after making a Z-axis reference run for DLM4 manually.
D1-118549501 If you wanted to lay down the nozzles for gantry 1 (TH head) an error
message came up for gantry 2 (DLM4 head).
D1-118850801 The pickup angle on table 2 was not correct.
D1-118910949 An interrupted board did not move out of the machine.
D1-118928201 The machine stopped with the error message: 40024 Component
prevents required star reference run
.
D1-118963801 The z pickup position was smaller than the minimal allowed value.
D1-118995201 CLI was not working on the station (the threshold values were not set).
D1-119039732 The service positions 1 and 2 were not correct.
D1-119064834 When the board was loaded into the machine it stopped with this error
message: 42412 Move is not allowed due to possible
collision
.
D1-119067001 Within the single calibration the segment-/head-offsets were 0.
D1-119125201 The station ignored the "incomplete" flag of the component shape.
D1-119139610 Minimum Component Sensor Value for HeadCareStation and machine was
different.
D1-119170901 There was an "'unhandled exception" during production.

Station Software 709.1 / Version Description Ausgabe 05/2016 Edition
49
D1-119185512 The gantry could not be moved when a high component which covers the
component sensor should be placed.
D1-119215101 eSW: error message 30455 The operating system of the
processor has a fatal error
.
D1-119244401 The machine stopped without error message after having laid down the
component on the SST47.
D1-119261101 The calibration with a CPP head led to an exception.
D1-119273701 The component was not yet stable on the plate when the camera flashed.
D1-120686001 In version 708 the parameter for the CLI on the GUI changed. The quantity
could only be changed by the number of remaining components and no longer
by the length of the remaining tape.
D17753-29901 Z-axis error during production: 30461 position is out of range.
D17839-6712 Some components of location 2 and location 3 (for CPP head) were omitted.
D17928-9401
D1-116399603
eSW: sporadically there was a Ieff error with an analog light barrier.
D17928-9714 The nozzle height could not be tested when the machine changed the nozzle.
Table 8-3: Corrected errors: 709.0 Hotfix 2
709.0 Hotfix 1
Error no. Error description
D1-114000301 Gantry 2 reported a crash (the gantries touched each other slightly without any
consequence).
D1-115190701
D17753-24601
D1-118049717
eSW: Sporadically, the status request for the nozzle changer reported an error
for magazine 5.
D1-115823017 The C&P20 head unnecessarily changed nozzles when one segment is
disabled.
D1-117929201 The station sporadically locked up during pickup from WPC.
D1-117970440 The machine stopped with this error message: 37800 Machine stopped
due to too many repetitive errors on segment 5
.
D1-118190601 eSW: in Convoy mode, the boards were not clamped in the placement area.
D1-118205601 TX: The software hung up during night shift. It was necessary to reboot the
machine.
D1-118232601 DLM4 placement was not stable. There was a software crash during the
production run.
D1-118376113 The component sensor of a C&P14 head could not be calibrated when the
machine was single sided. Error: 30341: position is out of range
(X-axis of gantry 1).
Table 8-4: Corrected errors 709.0 Hotfix 1
Station Software 709.1 / Version Description Ausgabe 05/2016 Edition
50
9 Important Terms and Abbreviations
CA4 Machine type of the Chip Assembly (CA)-series with 4 gantries
CA4 eWLP Machine type of the Chip Assembly (CA)-series with 4 gantries
and WLFO (customer project, no release for series production)
C&P Collect & Place
CPP Collect & Place & Pick & Place
DC Dual Conveyor
DX1/DX2 Machine type with 1 or 2 gantries
DX4 Machine type with 4 gantries
EDIF Electronic Design Interchange Format
eWLP embedded Wafer Level Process
FCCS Field Camera Calibration System
GUI Graphical User Interface
HFH High Force Head
HW Hardware
MGCU Modular Gantry Control Unit
MHCU Modular Head Control Unit
MTC Matrix Tray Changer
OIS Operator Information System
PA Processing area
PCB Printed circuit board
Placement mode:
2-in-1
When a machine runs in I-Placement mode it is possible to
perform manual operations for one side / gantry.This placement
mode is also called "independent".
Placement mode:
Alternating
Placement mode in a dual gantry placement area, in which both
gantries place components on both boards in a dual conveyor.
First, both gantries place all assigned components on the board
in lane one and then on the board in lane two.
Placement mode:
Borrow
Performance
A line runs in I-Placement mode and to get a balanced troughput
between the left and right conveyor lanes, e.g. the last machine
runs in Alternating mode and places components in this
placement area on the board of the other lane.
Placement mode:
I-Placement
Placement mode in a dual gantry placement area in which each
gantry only places components on the board of the assigned
conveyor lane.
SC Single Conveyor
SC SIPLACE Setup Center (external setup control system)
SW Software
SWS SIPLACE Wafer System
SX1/SX2 Machine type with 1 or 2 gantries
SX4 Machine type with 4 gantries