TUT-CP842-Oper guide-preliminary.pdf.pdf - 第40页

Setting the Device T able Mode Select the method in which the device tables are to be used (T able mode) in accordance with production. <Explanation of table modes> Joint mode: The device tables D1 and D2 are opera…

100%1 / 91
Setting the Scheduled Production Quantity
Specify the number of panels that are scheduled to be produced using the
production program currently selected for use. The machine stops when the
scheduled production quantity has been produced.
Procedure
1. Select [Program] from the [Main] screen.
2. Press [Chg Scheduled Panels].
3. Input the scheduled production quantity using the numeric
keypad that appears.
4. Press [OK].
5. The numeric keypad will then disappear from the screen and the
scheduled production quantity that has been specified will be
enabled.
6. Press [Close] to return to the [Main] screen.
Note: If the scheduled production quantity is set to "0". Production continuous
indefinitely. The machine will continue to produce panels until the
operator quits production.
Chapter 3: Preparing for Production
Preliminary
3-9CP-842E/842ME Operators Guide
Setting the Device Table Mode
Select the method in which the device tables are to be used (Table mode) in
accordance with production.
<Explanation of table modes>
Joint mode:
The device tables D1 and D2 are operated together as a single device table.
This mode is used for production programs that have a large number of parts.
Joint resupply mode:
Joint resupply mode is basically the same as the standard joint mode in that
both tables are used in production. However, in joint resupply mode, the table
which is inactive in moved to the retract position until required, and feeders
can be set or removed at this position without interrupting production.
Device Change mode:
One of the device tables D1 or D2 is used in production while the other table
is kept in the standby position for use as a reserve. When a part runs out on
the device table in use, a switch is made to the other device table and
production continues. The relevant device slots on each table must be loaded
with the same parts.
Changeover mode:
One of the device tables D1 or D2 is used for production while parts are
switched on the other to ready it for the next production run.
Note: When either the Device Change Mode or the Changeover Mode is
selected, the [Original Table] setting described below must also be
specified.
Procedure
1. Select [Operation] from the [Main] screen.
2. Select the table mode that is to be used in production. Select
either "Joint", "Device Change", or "Changeover".
3. Press [Close] to return to the [Main] screen.
3.3 Device Tables
Chapter 3: Preparing for Production
Preliminary
3-10 CP-842E/842ME Operators Guide
Selecting the Original Table
When either Device Change or Changeover mode is selected, the device table
to be used in production first must be selected.
Procedure
1. Select [Operation] in the [Main] screen.
2. At the [Original Table] section, selct the device table which has
production priority as either “Stage 1” or “Stage 2”.
3. Press [Close] to return to the [Main] screen.
Chapter 3: Preparing for Production
Preliminary
3-11CP-842E/842ME Operators Guide