D4+circuit(2006).pdf - 第75页

2 - 41 TS-01 0101LD 3 T em perat ure sen sor, head, gantr ies 1 - 4 Modified Status Date CAD file : TS-010101 LD3.DWG Orig./Repl. f./Repl. by Stand. Nam e Check. Stromlaufplan/Circuit diagram Mat. no. : Author H i Date S…

100%1 / 181
2 - 40
PW-010101LD3 Nozzle changer
BU
03032438
Control board
Nozzle changer
00317353 (ka)
Ctrl_ValveNC 1a
S_NCRight (closed)
S_NCLeft (open)
Ctrl_ValveNC 1b
BK3
X8qb
2BK
4BK
CAN I/O module 2
X3qb
X8qb
1 BK
S_NCRight (closed)
S_NCLeft (open)
CAN I/O module 2
1
2
X3qb
BK
4
1
2
X19df
WH
BN
GN
YE
GY
PK
6
5
Valve control
GND
+24V
1
NC open
3
4
2
spare
X1ka
9
8
7
GND
NC closed
YE
GN
GY
BN
WH
PK
00331653 (ka)
Location 4
Nozzle changer (4a)
4
3
X20df
2
1
5
6
OG
WH
n.u.
CAN I/O module 2
S_NCLeft (open)
S_NCRight (closed)
Ctrl_ValveNC 4a
BK6
X8qb
3BK
BK5
X3qb
BK
OG
3
6
5
PW-010101LD3
08.05.06
08.05.06
08.05.06
08.05.2006
Copyright reserved
SIEMENS AG
X8qb
8
7
X3qb
4
CAN I/O module 2
BK
BK
BKS_NCLeft (open)
S_NCRight (closed)
Ctrl_ValveNC 4b
BK
BK
Ctrl_ValveNC 2a
S_NCLeft (open)
S_NCRight (closed)
16C
X200
GND
6B
+24V
GND
4B
WH
OG
WH
X8rb
X4rb
1
2
1
BK
BK
BK
4GN3
03032417
WH
OG
n.u.
6
5
4
3
2
1
X20bf
5
6
4
PK
GY
YE
GY
GN
YE
PK
9
6
8
7
5
Valve control
GND
NC closed
GND
03032415
BK
OG
WH
OG
BK
WH
BK
BK
X19bf
2
1
WH
BN
6
n.u.
2
4
3
5
X18bf
1
WH
BK
WH
BK
OG
BK
X17bf
5
6
PK
GY
2
1
3
4
GN
YE
BN
WH
BN
BU
WH
X1ha
2
3
1
Nozzle changer (3a)
00331653 (ha)
00317353 (ha)
Nozzle changer
Control board
Location 3
NC open
spare
+24V
1BN
BU
WH
GY
GN
YE
PK
8
9
6
7
4
5
3
2
X1ga
+24V
Valve control
GND
NC closed
NC open
GND
spare
00331653 (ga)
Location 2
Nozzle changer (2a)
00317353 (ga)
Nozzle changer
Control board
CAN I/O module 2
03032354
Distributor sector 2 (bf)
ModifiedStatus Date
CAD file : PW-010101LD3.DWG
Orig./Repl. f./Repl. byStand.Name
Check.
Stromlaufplan/Circuit diagram
Mat. no. :
Author Hi
Date
Sh.
Sh.
SIPLACE D4
1
1
Nozzle changer
Document st.
Product st.
Function st.
1. Hi
Hi1.
Hi1.
BK
03032436
WH
OG
1
n.u.
5
6
2
3
4
X18df
4
6
5
GY
PK
YE
PK
YE
GN
GY
9
7
8
5
6
Valve control
GND
NC closed
GND
3
1
2
X17df
WH
BN
GN
WH
BU
BN
X1fa
2
3
4
1
Nozzle changer (1a)
Location 1
Control board
Nozzle changer
00317353 (fa)
00331653 (fa)
NC open
spare
+24V
BK
BK
WH
BK
WH
BK
WH
BK
OG
BK
6C
WH
X400
16D
OG
+24V
GND
6B
GND WH
Distributor sector 4 (df)
03032354
BK6S_NCRight (closed)
Ctrl_ValveNC 3b
S_NCLeft (open)
S_NCRight (closed)
Ctrl_ValveNC 3a
X8rb
4
8
7
BK
BK
BK
CAN I/O module 2
X4rb
X8rb
3BK
S_NCLeft (open)
Ctrl_ValveNC 2b
S_NCLeft (open)
S_NCRight (closed)
CAN I/O module 2
X4rb
5BK
CAN I/O module 2
X8rb
X4rb
2
4
3
BK
S
ee page 3-3
S
ee page 3-9
2 - 41
TS-010101LD3 Temperature sensor, head, gantries 1 - 4
ModifiedStatus Date
CAD file : TS-010101LD3.DWG
Orig./Repl. f./Repl. byStand.Name
Check.
Stromlaufplan/Circuit diagram
Mat. no. :
Author Hi
Date
Sh.
Sh.
SIPLACE D4
1
1
Temperature sensor, head
Document st.
Product st.
Function st.
1. Hi
Hi1.
Hi1.
1
Key
n.u.
Key
BK
n.u.
ϑ
BK
6
+5V
3Enable_1
4
2
1
Key
n.u.
BK
Key
BK
n.u.
ϑ
X22cc
Module
03003536
Gantry head distributor
Gantry 4
03038002 (dc)
X5cc
108
GND
4
5
6
Enable_1 3
2
TQM167 SIPLACE
Embedded
03038002 (cc)
Gantry 3
Gantry head distributor
120-pole
+5V
Module
03003536
X5ac
108
GND
4
5
6
Enable_1 3
2
TQM167 SIPLACE
Embedded
03038002 (ac)
Gantry 1
Gantry head distributor
120-pole
+5V
1
Key
n.u.
Key
BK
n.u.
ϑ
BK
TQM167 SIPLACE
X22dc
03003536
Embedded
Module
120-pole
108
X5dc
5
GND
X22bc
2
3
1
TQM167 SIPLACE
4
6
5
Enable_1
n.u.
Key
Key
BK
n.u.
BK
ϑ
03038002 (bc)
Gantry 2
Gantry head distributor
X22ac
TS-010101LD3
08.05.06
08.05.06
08.05.06
08.05.2006
Copyright reserved
SIEMENS AG
Gantries 1 - 4
Module
03003536
Embedded
X5bc
108
120-pole
+5V
GND
S
ee page 5-26
S
ee page 5-26
S
ee page 5-26
S
ee page 5-26
S
ee page 5-16
S
ee page 5-16
S
ee page 5-16
S
ee page 5-16
2 - 42
LPET-010102LD3 PCB single conveyor/PCB dual conveyor, track 1,
conveyor control TSP 301 (sh. 1 of 10)
UPSTREAM STATION
CONVEYOR TRACK 1
CONVEYOR TRACK 1
UPSTREAM STATION
M_1
NOT_READY-
BOARD_PASS-
BOARD_PASS+
M_1
N_GND
BOARD_AVAILABLE-
BOARD_AVAILABLE+
10
9
8
5
6
7
4
3
M_1
19
NOT_READY+
CONVEYOR TRACK 1
N_GND_24DC
N_ANFORDERUNG
DOWNSTREAM STATION
X4ao
2
1
20
N_STOERSCHLEIFE
N_STOERSCHLEIFE
N_GND
E_NS_ERLAUBNIS
N_ABGEGEBEN
E_NS_ ANGEKOMMEN
18
17
16
15
12
13
14
11
10
CONVEYOR TRACK 1
X2ao
N_SMEMA_DC
N_+24DC
5
9
8
6
7
3
4
2
1
DOWNSTREAM STATION
M_1
N_GND_24DC
1
X11ao
MOT1+
2
MOT1-
3
4
MOT2+
5
6
MOT2-
7
8
MOT3+
9
10
MOT3-
11
12
MOT4+
13
14
MOT4-
15
16
MOT5+
17
18
MOT5-
19
20
SM_A+
25
40
38
27
2
26
3
1
X13ao
39
40
38
27
2
26
3
X53kt
1
P24_1
M_1
OUT (11)
OUT (0)
IN (31)
IN (0)
OUT (23)
M_1
OUT (12)
IN (55)
IN (32)
P24_1
00363420
00363431
SIEMENS
SMEMA
1 - 2 4 - 5 7 - 8
2 - 3 5 - 6 8 - 9
J1 conveyor interface
3
1
2
Fault signal loop
J3 1 - 2
(ao) 03042306
Conveyor control TSP-301
64
1
X10ao
I/O bus for extension card TSP 301E
J2 conveyor interface
2 - 3 5 - 6 8 - 9
1 - 2 4 - 5 7 - 8
SMEMA
SIEMENS
3
1
2
6
9
4
5
7
8
Conversion board
"Conveyor"
(Key)
26
SM_A-
27
28
SM_B+
29
30
SM_B-
31
32
33
34
X51kt
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
25
26
27
28
29
30
31
32
33
34
1
50
49
48
1
37
34
2
3
X12ao X52kt
1
50
49
48
3
37
34
2
00359425
(kt) 00359425
1
2
3
4
5
6
7
8
9
00359425
39
00363419
Status
02.
01.
01.
Doc. status
Modified
Function status
Product status
Date
05.12.2006
08.05.2006
08.05.2006 Hi
Hi
Hi
Name Stand.
Check.
Date
Author Hi
08.05.2006
CAD file:
Mat. no.:
Orig./Repl.f/Replaced by
LPET-010102LD3
Sh.
Sh.10
1
V_STOERSCHLEIFE
V_ANGEKOMMEN
V_GND_24DC
V_STOERSCHLEIFE
V_GND_24DC
V_+24DC
V_SMEMA_DC
12
13
14
11
10
9
8
5
6
7
4
3
X1ao
2
1
V_ERLAUBNIS
15
16
17
E_VS_ABGEGEBEN
18
E_VS_ANFORDERUNG
19
V_GND
20
10
X3ao
BOARD_PASS+
V_GND
M_1
BOARD_PASS-
NOT_READY-
BOARD_AVAILABLE-
BOARD_AVAILABLE+
NOT_READY+
5
9
8
6
7
3
4
2
1
M_1
LPET-010102LD3_SH01.DWG
Stromlaufplan/Circuit diagram
SIPLACE D4
PCB single conveyor / PCB dual conveyor, track 1
Conveyor control TSP-301
(Key)
SIEMENS interface
SMEMA interface
SIEMENS interface
SMEMA interface
Motor, "input conveyor"
Motor, "placement sector 1"
Motor, "intermediate conveyor"
Motor, "placement sector 2"
Motor, "output conveyor"
Step motor, "width adjustment"
To conversion board
"Conveyor"
To conversion board
"Conveyor"
ON
12345678
S4 DIL switch
SIEMENS AG
Copyright reserved
See page 5-32
See page 5-12
F
See page 2-53