D4+circuit(2006).pdf - 第81页

2 - 47 LPET-010102LD3 PCB sing le conve yor/PCB dual con veyor, track 1, conversi on boar d "conveyor rail A“, stationa ry conve yor side on the right ( sh. 6 o f 10) Stromlaufplan/Circuit diagram Status Doc. status…

100%1 / 181
2 - 46
LPET-010102LD3 PCB single conveyor/PCB dual conveyor, track 1,
conveyor control TSP 301 (sh. 5 of 10)
Stromlaufplan/Circuit diagram
Conveyor control TSP-301
X36kt
2
1
Key
Placement sector 2
SOKO/options
5
14GND
A2.36
A2.35
A2.34
Key
18
17
16
15
A2.20
A2.19
A2.18
A2.15
A2.17
A2.16
A2.26
12
13
11
10
7
9
8
6
SOKO/options
Placement sector 2
A2.25
+24V-
A2.24
X35kt
Key
4
3
2
1
5
14GND
A2.36
A2.35
A2.34
18
17
Key
16
15
A2.20
A2.19
A2.18
12
13
11
10
A2.15
A2.17
A2.16
A2.26
7
9
8
6
X37kt
A2.25
+24V-
A2.24
4
3
2
1
Key
X 29kt ... X33kt not used
X6kt ... X18kt not used
WH
BK
5
6
4
3
X41kt
2
1
+24V-
Key
GND
A1.43
Width adjustment
Adjusting 1, valve Adjusting 2, valve
Width adjustment
GND 6
5
WH
A1.44
+24V-
BK
2
Key
3
4
X45kt
1
X46kt
GND 6
5
BU
GND 6
5
Width adjustment
Adjusting 1, cylinder switch
X42kt
2A1.19
+24V- 3
4
1
BK
Key
Width adjustment
Adjusting 2, cylinder switch
2A1.20
+24V- 3
4
1
Key
BU
BK
BN
00363777
00363779
00363780
00363778
BN
X47kt
Width adjustment
Adjusting 1, sensor cheek
55
GND
6
00363775
BU
GND 6
X43kt
+24V-
4
3
A1.21
1
2
BN
Key
BK
+24V-
4
3
A1.22
1
2
Adjusting 2, sensor cheek
Width adjustment
00363776
BU
Key
BN
BK
X48kt
GND 6
5
00363269
Key
GND 6
5
Limit switch, right spindle
Width adjustment 1
X44kt
2A1.23
+24V-
3
4
1
BN
WH
Limit switch, left spindle
2A1.24
+24V- 3
4
1
Width adjustment 2
00363293
BN
WH
Key
4
1 1
4
00365299
4
SM_B+
5
6
SM_A-
SM_A+
3
2
WH
X40kt
1
BK
OG
X49kt
7
8
9
10
SM_B-
BN
GN
YE
4
1
3
2
5
6
7
8
9
BN
WH
GN
YE
YE
BU
BN
RD
WH
GN +
-
-
+
+
-
-
+
A
A
B
B
"Width adjustment"
00360901
Step motor
5
GND 6
X19kt
+24V-
A1.17
4
3
Key
WH
2
1
BN
1
4
"Width adjustment"
00365002
Limit switch
Status
Doc. status
Modified
Function status
Product status
Date
Hi
Hi
Hi
Name Stand.
Check.
Date
Author Hi
CAD file:
Mat. no.:
Orig./Repl.f/Replaced by
Sh.
Sh.10
5
(kt) 00359425
Conversion board, "conveyor"
4
6
8
7
5
3
2
X34kt
1
9
10
A2.23
A2.22
A2.21
Key
+24V-
11
12
13
14
15
16
17
18
GND
A2.9
A2.10
A2.11
A2.12
A2.13
A2.14
A2.31
A2.32
A2.33
Key
Placement sector 1
SOKO/options
A2.14 12
A2.33
18
17
Key
A2.32
A2.31
GND
16
15
14
13
A2.13
A2.12
A2.11
A2.10
11
10
8
9
A2.9
A2.23
+24V-
A2.22
5
6
7
4
3
Placement sector 1
A2.21
SOKO/options
to plug X53kt see sheet 4
All connections from A2.xx
to plug X52kt see sheet 3
All connections from A1.xx
PLEASE NOTE:
All connections from SM_xx
to plug X51kt see sheet 3
PLEASE NOTE:
PCB single conveyor / PCB dual conveyor, track 1
Key
Key
01.
01.
02.
08.05.2006
08.05.2006
05.12.2006
08.05.2006
LPET-010102LD3_SH05.DWG
Copyright reserved
SIEMENS AG
SIPLACE D4
LPET-010102LD3
00365108 00365109
(Single conveyor)
(Dual conveyor) (Dual conveyor)
(Single conveyor)
See page 5-12
See page 2-44
See page 2-44
See page 2-45
2 - 47
LPET-010102LD3 PCB single conveyor/PCB dual conveyor, track 1, conversion board
"conveyor rail A“, stationary conveyor side on the right (sh. 6 of 10)
Stromlaufplan/Circuit diagramStatus
Doc. status
Modified
Function status
Product status
Date
Hi
Hi
Hi
Name Stand.
Check.
Date
Author Hi
CAD file:
Mat. no.:
Orig./Repl.f/Replaced by
Sh.
Sh.10
6
Conversion board, "conveyor rail"
WH
BN
5
6
4
3
X1kv
2
1
Key
MOT1-
MOT1+
MOT5-
MOT5+
MOT4-
MOT4+
MOT3-
MOT3+
MOT2-
MOT2+
MOT1-
MOT1+
(sheet 3)
"Conveyor"
Conversion board
To plug X54kt
00363667
(kv) 00359424
Side panel A
GND
EA0
EA2
EA4
EA6
EA8
EA1
EA3
EA5
EA7
EA9
+24V-
00359425
M
Cable, belt motor
Input conveyor
00362331
22
31
34
33
32
29
30
28
27
24
26
25
23
3
17
21
20
19
18
15
16
14
13
8
10
12
11
9
7
6
5
4
X16kv
1
2
Placement sector 1
4
Key
MOT2-
WH
6
5
MOT2+
Cable, belt motor
BN
3
2
X2kv
1
00362332
M
Intermediate conveyor
4
Key
MOT3-
WH
6
5
MOT3+
Cable, belt motor
BN
3
2
X3kv
1
00362334
M
Placement sector 2
4
Key
MOT4-
WH
6
5
MOT4+
Cable, belt motor
BN
3
2
X4kv
1
00362336
M
Output conveyor
4
Key
MOT5-
WH
6
5
MOT5+
Cable, belt motor
BN
3
2
X5kv
1
00362337
M
2
BK
BU
5
6
4
3
Light barrier
Key
00370072
BK
Receiver, output conveyor
X10kv
1
2
Key
BU
5
6
4
3
Light barrier
00370071
BK
Receiver, placement sector 2
X9kv
1
2
Key
BU
6
5
4
3
EA0 2
BK
2
BK
Light barrier
00370070
Receiver, intermediate conveyor
X8kv
1
BU
6
5
3
4
Light barrier
00370069
Key
Receiver, placement sector 1
X7kv
1
Key
BU
6
5
3
4
Light barrier
00370068
Receiver, input conveyor
X6kv
1
BN
+24V-
BN
BN
BN
BN
GND
GND
EA1
+24V-
GND
EA2
+24V-
GND
EA3
+24V-
GND
EA4
+24V-
EA7
GND
+24V-
EA9
GND
+24V-
EA8
GND
+24V-
EA5
EA6
GND
+24V-
GND
+24V-
BN
2
Key
5
6
4
3
Not used
1
2
X15kv
5
6
4
3
Not used
Key
1
2
X14kv
Key
WH
6
5
4
3
GN
2
GN
2
Limit switch, width adjustment
00362345
1
X13kv
WH
Key
BN
6
5
3
4
Receiver module, placement sector 2
00363091
Light barrier
1
X12kv
WH
BN
6
5
3
4
Receiver module, placement sector 1
00363090
Light barrier
Key
1
X11kv
4
1
Conversion board, "conveyor rail A"
Stationary conveyor side on the right
PCB single conveyor / PCB dual conveyor, track 1
01.
01.
02.
08.05.2006
08.05.2006
05.12.2006
08.05.2006
LPET-010102LD3_SH06.DWG
Copyright reserved
SIEMENS AG
SIPLACE D4
LPET-010102LD3
See page 5-11
See page 2-44
2 - 48
LPET-010102LD3 PCB single conveyor/PCB dual conveyor, track 1, conversion board
"conveyor rail B“, stationary conveyor side on the right (sh. 7 of 10)
Stromlaufplan/Circuit diagram
Conversion board, "conveyor rail B"
Status
Doc. status
Modified
Function status
Product status
Date
Hi
Hi
Hi
Name Stand.
Check.
Date
Author Hi
CAD file:
Mat. no.:
Orig./Repl.f/Replaced by
Sh.
Sh.10
7
Conversion board, "conveyor rail"
WH
BN
5
6
4
3
X1kw
2
1
Key
MOT1-
MOT1+
MOT5-
MOT5+
MOT4-
MOT4+
MOT3-
MOT3+
MOT2-
MOT2+
MOT1-
MOT1+
(sheet 3)
"Conveyor"
Conversion board
To plug X55kt
00363668
(kw) 00359424
Side panel B
GND
EA0
EA2
EA4
EA6
EA8
EA1
EA3
EA5
EA7
EA9
+24V-
00359425
Input conveyor
00362331
22
31
34
33
32
29
30
28
27
24
26
25
23
3
17
21
20
19
18
15
16
14
13
8
10
12
11
9
7
6
5
4
X16kw
1
2
Not used
4
Key
MOT2-
6
5
MOT2+
3
2
X2kw
1
Not used
4
Key
MOT3- 6
5
MOT3+
3
2
X3kw
1
Not used
4
Key
MOT4- 6
5
MOT4+
3
2
X4kw
1
Output conveyor
4
Key
MOT5-
WH
6
5
MOT5+
BN
3
2
X5kw
1
00362337
2
5
6
4
3
Key
X10kw
1
2
Light barrier
00370066
Transmitter, placement sector 2
Key
BU
6
5
4
3
EA0 2
2
Light barrier
00370065
Transmitter, intermediate conveyor
X8kw
1
6
5
3
4
Light barrier
00370064
Key
Transmitter, placement sector 1
X7kw
1
Key
BU
6
5
3
4
Light barrier
00370063
Transmitter, input conveyor
X6kw
1
BN
+24V-
BN
GND
GND
EA1
+24V-
GND
EA2
+24V-
GND
EA4
+24V-
EA7
GND
+24V-
EA9
GND
+24V-
EA8
GND
+24V-
EA5
EA6
GND
+24V-
GND
+24V-
BN
2
Key
5
6
4
3
1
2
X15kw
5
6
4
3
1
2
X14kw
Key
WH
6
5
4
3
2
2
Limit switch, width adjustment
00362345
1
X13kw
BU
Key
BN
6
5
3
4
Transmitter, output conveyor
00370067
Light barrier
1
X12kw
6
5
3
4
Key
1
X11kw
4
1
Stationary conveyor side on the right
GND 6
1
+24V-
EA3
5
4
2
3
X9kw
Key
00363094
Transmitter, placement sector 2
Light barrier
00363092
Transmitter, placement sector 1
Light barrier
BN
WH
WH
BN
Cable, belt motor
Cable, belt motor
PCB single conveyor / PCB dual conveyor, track 1
BU
BN
BU
BN
Not used
Not used
Key
01.
01.
02.
08.05.2006
08.05.2006
05.12.2006
08.05.2006
LPET-010102LD3_SH07.DWG
Copyright reserved
SIEMENS AG
SIPLACE D4
LPET-010102LD3
(Single conveyor only)
(Single conveyor only)
See page 5-11
See page 2-44