_414214_AVK3 服务手册.pdf - 第114页
6 . 8 Secret Screen Service Functions (CONFIDENTIAL) SERVICE MANUAL A VK3 6.8−5 D77SEC−85−080−A0 6.8.5 NC Axis Used / Unused Setting 1. Select “MANU” → ”REQUEST” → “F8” → “F1” (MACHINE INITIALIZE V ALUE SETTING) → “F3” (…

6.8 Secret Screen Service Functions (CONFIDENTIAL)
SERVICE MANUAL
AVK3
6.8−4
D77SEC−85−080−A0
6.8.4 Initial Data Set
1. Select “MANU” → ”REQUEST” → “F8” → “F1” (MACHINE INITIALIZE VALUE SETTING) →
“F3” (PRUODUCTION CONDITIONS SETTING) → “F2” (CLEAR MEMORY) → “F7” → “A”
→ “F7” → “J” → “F7” → “F3” (INITIAL DATA SET) on the main control panel.
<F1> <F2> <F3> <F4> <F5> <F6> <F7> <F8>
YYYY − MM − DD HH : MM
THIS IS TO SET INITIAL DATA.
MANUAL : 1 BLOCK << M/C INI. VAL. SET >>
RETURN
TO DISP
SET INITIAL DATA.
INITIAL DATA SET
SETTING ATTEMPT? ( F1 : YES F2 : NO )
YES NO
Figure 6.8−3:Initial Data Set
Description of parameters
• This is a designation of whether all initial data will be set or not.
F1 : All initial data will be set.
F2 : All initial data will not be set.

6.8 Secret Screen Service Functions (CONFIDENTIAL)
SERVICE MANUAL
AVK3
6.8−5
D77SEC−85−080−A0
6.8.5 NC Axis Used / Unused Setting
1. Select “MANU” → ”REQUEST” → “F8” → “F1” (MACHINE INITIALIZE VALUE SETTING) →
“F3” (PRUODUCTION CONDITIONS SETTING) → “F5” → “A” → “X” → “I” → “S” → “F5”
on the main control panel.
<F1> <F2> <F3> <F4> <F5> <F6> <F7> <F8>
YYYY − MM − DD HH : MM
MOVE CURSOR. PUSH ENTER KEY.
MANUAL : 1 BLOCK << M/C INI. VAL. SET >>
RETURN
TO DISP
NC AXIS USED / UNUSED SETTING
(X AXIS) 1:YES 2:NO
(Y AXIS) 1:YES 2:NO
(ZL AXIS) 1:YES 2:NO
(ZR AXIS) 1:YES 2:NO
(T AXIS) 1:YES 2:NO
(U AXIS) 1:YES 2:NO
(H AXIS) 1:YES 2:NO
(θH AXIS) 1:YES 2:NO
(θA AXIS) 1:YES 2:NO
(WH AXIS) 1:YES 2:NO
(WA AXIS) 1:YES 2:NO
(V AXIS) 1:YES 2:NO
Figure 6.8−4:NC Axis Used / Unused Setting
Description of parameters
• This is a designation of whether each NC axis will be used or Unused.
1 : Used
2 : Unused

6.8 Secret Screen Service Functions (CONFIDENTIAL)
SERVICE MANUAL
AVK3
6.8−6
D77SEC−85−080−A0
6.8.6 Driver Gain Setting
1. Select “MANU” → ”REQUEST” → “F8” → “F1” (MACHINE INITIAL SETTINGS) →“F3”
(PRODUCTION CONDITIONS SETTING) → “F6” → “G” → “A” → “I” → “N” → “F6” on the
main control panel.
<F1> <F2> <F3> <F4> <F5> <F6> <F7> <F8>
YYYY − MM − DD HH : MM
SELECT FUNCTION KEY.
MANUAL : 1 BLOCK << M/C INI. VAL. SET >>
RETURN
TO DISP
F1.
F2.
F3.
F4.
F5.
F6.
F7.
F8.
MOVEMENT DRIVER GAIN SETTING
STOPPING DRIVER GAIN SETTING
RETURN TO DISPLAY
DRIVER GAIN SETTING
MOVEMENT
GAIN
STOPPING
GAIN
Figure 6.8−5:Driver Gain Setting
Description of parameters
• This is a designation of whether movement driver gain setting or stopping driver gain move-
ment will be done.
F1 : Movement driver gain will be done.
F2 : Stopping driver gain setting will be done.
=NOTE=
Refer to ’MAINTENANCE GUIDE (CONTROL) / 5.1 AC Servo Gain Adjustment’ in
Chapter 5.