_414214_AVK3 服务手册.pdf - 第54页

4.3 XY T able Origin Check SERVICE MANUAL A VK3 4.3−1 D77SEC−83−D00−A0 4.3 XY T able Origin Check D77SEC−83−D00−A0 Sentence No. 4.4 XY T able Overlimit Adjustment 4.3 XY T able Origin Check X axis (+) limit sensor X axis…

100%1 / 126
4.2 Axis Origin Adjustment
SERVICE MANUAL
AVK3
4.2−2
D77SEC−83−1Z0−A0
= MEMO =
4.3 XY Table Origin Check
SERVICE MANUAL
AVK3
4.3−1
D77SEC−83−D00−A0
4.3 XY Table Origin Check
D77SEC−83−D00−A0
Sentence No.
4.4 XY Table Overlimit
Adjustment
4.3 XY Table Origin
Check
X axis (+) limit sensor
X axis (+) safety limit switch
X axis origin sensor
X axis (−) safety limit switch
X axis (−) limit sensor
Nut D
N cup
Motor axis Ball screw axis
Y axis (+) limit sensor
Y axis (+) safety limit switch
Y axis origin sensor
Y axis (−) safety limit switch
Y axis (−) limit sensor
Nut D
XY table origin check
1. Turn the power [ON].
2. Turn ”SERVO MOTOR” on the main con-
trol panel [OFF] then, open the cover and
move the XY table to any position except
origin.
=NOTE=
Make sure that the LED of the limit
sensor is illuminated.
3. Close the front cover and press START
on the main control panel. (This clears the
safety stop).
4. Press “RESET” on the main control pan-
el and turn “SERVO MOTOR” on the
main control panel [ON].
5. Press “MANU” and “ORG” on the main
control panel.
=NOTE=
Make sure that the asterisks of the
X and Y axes blink on the main con-
trol panel display when XY table re-
turns to origin.
=NOTE=
Be careful of safety, since all axes
will return to their origin.
4.3 XY Table Origin Check
SERVICE MANUAL
AVK3
4.3−2
D77SEC−83−D00−A0
= MEMO =