_414214_AVK3 服务手册.pdf - 第116页

6 . 8 Secret Screen Service Functions (CONFIDENTIAL) SERVICE MANUAL A VK3 6.8−7 D77SEC−85−080−A0 6.8.7 Width Initial Data Setting 1. Select “MANU” → ”REQUEST” → “F8” → “F1” (MACHINE INITIALIZE V ALUE SETTING) → “F1” (OPE…

100%1 / 126
6.8 Secret Screen Service Functions (CONFIDENTIAL)
SERVICE MANUAL
AVK3
6.8−6
D77SEC−85−080−A0
6.8.6 Driver Gain Setting
1. Select “MANU” ”REQUEST” “F8” “F1” (MACHINE INITIAL SETTINGS) “F3”
(PRODUCTION CONDITIONS SETTING) “F6” “G” “A” “I” “N” “F6” on the
main control panel.
<F1> <F2> <F3> <F4> <F5> <F6> <F7> <F8>
YYYY MM DD HH : MM
SELECT FUNCTION KEY.
MANUAL : 1 BLOCK << M/C INI. VAL. SET >>
RETURN
TO DISP
F1.
F2.
F3.
F4.
F5.
F6.
F7.
F8.
MOVEMENT DRIVER GAIN SETTING
STOPPING DRIVER GAIN SETTING
RETURN TO DISPLAY
DRIVER GAIN SETTING
MOVEMENT
GAIN
STOPPING
GAIN
Figure 6.8−5:Driver Gain Setting
Description of parameters
This is a designation of whether movement driver gain setting or stopping driver gain move-
ment will be done.
F1 : Movement driver gain will be done.
F2 : Stopping driver gain setting will be done.
=NOTE=
Refer to ’MAINTENANCE GUIDE (CONTROL) / 5.1 AC Servo Gain Adjustment’ in
Chapter 5.
6.8 Secret Screen Service Functions (CONFIDENTIAL)
SERVICE MANUAL
AVK3
6.8−7
D77SEC−85−080−A0
6.8.7 Width Initial Data Setting
1. Select “MANU” ”REQUEST” “F8” “F1” (MACHINE INITIALIZE VALUE SETTING)
“F1” (OPERATION CONDITIONS SETTING) →→“F4” (WIDHT SETTING) “F3” “W”
“I” “D” “T” “H” “F3” on the main control panel.
<F1> <F2> <F3> <F4> <F5> <F6> <F7> <F8>
YYYY MM DD HH : MM
WIDTH INITIAL DATA SETTING
MANUAL : 1 BLOCK << M/C INI. VAL. SET >>
RETURN
TO DISP
SELECT USING ↑↓←→AND ENTER.
NO. 1
NO. 2
NO. 3
NO. 4
NO. 5
NO. 6
1
0
2
0
3
0
AXIS
NO
AXIS
NAME
TEACH
AXIS
AXIS NAME 1: XY RAIL AXIS 2: LOADER RAIL 3: UNLOAD. RAIL 4:L. CONV RAIL
0: NOT USED 5: UL. CONV RAIL 6: REFER. PIN 7: SUPPORT PIN 8:*************
9:************* 10:********* 11:************* 12:***********
SPEED
HIGH
ACCEL
DR
CT
AXIS
TYPE
TEACH
DRCT
RESOLU-
TION
12
0
15
0
15
0
1
0
1
0
1
0
10
0
10
0
10
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
44.01
0.00
10.00
0.00
10.00
0.00
PRINT
Figure 6.8−6:Width Initial Data Setting
Description of parameters
This is a designation to set axis No., axis name, speed, direction, teaching axis, axis type,
teaching direction, resolution of each auto width control axis.
6.8 Secret Screen Service Functions (CONFIDENTIAL)
SERVICE MANUAL
AVK3
6.8−8
D77SEC−85−080−A0
= MEMO =