Parameter Definition Front Start Offset (Vortex USC) The distance, in from the front edge of the board, at which the cleaner is to finish. Minimum -60mm Maximum 60mm Default 30mm Increment 1mm Rear Start Offset (Blue USC…

Parameter Definition
Screen Clean Rate 1 This parameter sets the number of print cycles between the cycling of the screen cleaner
for the first screen clean rate.
Minimum 0 (Screen cleaner off)
Maximum 200
Increment 1
Screen Clean Mode 2
(Including Vacuum)
This parameter sets the mode of operation of the screen cleaner for the second clean
mode. When selected this parameter opens a window that allows a screen clean option
sequence to be chosen. The sequence includes six stages, each of which may be one of
the following cleaning operations:
WET, DRY, VAC, NONE
A warning is given if the end stroke is wet.
Clean Screen Rate 2 This parameter sets the number of print cycles between the cycling of the screen cleaner
for the second screen clean rate.
Minimum 0 (Screen cleaner off)
Maximum 200
Increment 1
Print Vacuum mode This parameter determines the state of the vacuum during the print and flood stages of
the cycle. The parameter is only available if Adhesive has been selected in the Print
Mode parameter.
ON, OFF
Dry Clean Speed This parameter sets the speed of the screen clean dry wipe for optimization on the Blue
USC and the speed of the screen clean return stroke on the Vortex USC.
Minimum 10 mm/sec
Maximum 120mm/sec
Default 30mm/sec
Increments 1mm/sec steps
Wet Clean Speed This parameter sets the speed of the screen clean wet wipe for optimization.
Minimum 10 mm/sec
Maximum 100mm/sec
Increments 1mm/sec steps
Vac Clean Speed This parameter sets the speed of the screen clean Vacuum for optimization.
Minimum 10 mm/sec
Maximum 100mm/sec
Increments 1mm/sec steps
Clean After Downtime This function provides the facility for the screen to be cleaned automatically with a
preprogrammed clean after a preprogrammed idle time. Clean After Downtime only
becomes active after the machine has performed at least one print after it is powered up.
When selected this parameter opens a window that allows a clean after knead option
sequence to be chosen. The sequence includes six stages, each of which may be one of
the following cleaning operations:
WET, DRY, VAC, NONE
Clean After The Automatic screen clean after downtime process chosen in the above menu parameter
is carried out after a countdown of the number of minutes set in this parameter.
Minimum 5 mins.
Maximum 120 mins.
Increment 1 min.
Clean After Knead This function is active if the machine is running in automatic mode. If this option is
enabled and a paste dispense has been performed (either MANUAL or AUTOMATIC) a
paste knead is performed as defined by the paste knead parameters in the board file on
the next board immediately following the paste dispense. When selected this parameter
opens a window that allows a clean after knead option sequence to be chosen. The
sequence includes six stages, each of which may be one of the following cleaning
operations:
WET, DRY, VAC, NONE
Front Start Offset
(Blue USC)
This parameter determines the distance from the front edge of the board that the cleaning
stroke must start.
Minimum 0mm
Maximum 60mm
Increments 1mm
1.100 User Manual Software Version 6
MACHINE PROGRAMMING
MENU PARAMETERS

Parameter Definition
Front Start Offset
(Vortex USC)
The distance, in from the front edge of the board, at which the cleaner is to finish.
Minimum -60mm
Maximum 60mm
Default 30mm
Increment 1mm
Rear Start Offset
(Blue USC)
This parameter determines the distance from the rear edge of the board that cleaning must
complete.
Minimum 0mm
Maximum 60mm
Increments 1mm
Rear Start Offset
(Vortex USC)
The distance, in from the rear edge of the board, at which the cleaner is to start.
Minimum -60mm
Maximum 60mm
Default 30mm
Increment 1mm
Vortex Cassette Life
(Vortex USC)
This parameter sets the number of cleaning strokes that are applied before a cleaning
cassette is replaced.
Minimum 0
Maximum 200
Default 20
Increment 1
Vortex Clean Rate
(Vortex USC)
This parameter sets the frequency (in print cycles) at which screen cleaning occurs.
Minimum 0
Maximum 200
Default 0
Increment 1
Vortex Solvent Rate
(Vortex USC)
This parameter sets the frequency (in cleaning cycles) at which solvent is dispensed.
Minimum 1
Maximum 10
Default 1
Increment 1
Vortex Vacuum Start
(Vortex USC)
The distance, in from the front edge of the board, where vacuum is applied.
Minimum Vacuum Stop
Maximum Board Width
Default 0mm
Increment 1mm
Vortex Vacuum Stop
(Vortex USC)
The distance, in from the front edge of the board, where vacuum application is stopped.
Minimum -100mm
Maximum Vacuum Stop
Default 0mm
Increment 1mm
Vortex Vacuum Rate
(Vortex USC)
This parameter sets the frequency (in cleaning cycles) at which vacuum is applied.
Minimum 1
Maximum 10
Default 1
Increment 1
Vortex Vacuum Period
(Vortex USC)
This parameter sets the period for which vacuum is applied.
Minimum 1 sec
Maximum 10 secs
Default 5 secs
Increment 1 sec
Paste Dispense Rate This parameter sets the number of print cycles which occur between cycling of the paste
dispense system.
Minimum 0 (Dispenser switched off)
Maximum 100
Increment 1
Software Version 6 User Manual 1.101
MACHINE PROGRAMMING
MENU PARAMETERS

Parameter Definition
Paste Dispense Speed This parameter sets the speed at which the paste dispenser moves across the screen
thereby determining the amount of paste deposited on the screen.
Minimum 10mm/sec
Maximum 100mm/sec
Increment 1mm/sec
Paste Start This parameter determines start position of the paste dispense measured from the centre
line of the machine. The limits depend on the type of screen fitted.
Minimum
No adapter -255mm
255 -230mm
Sanyo -210mm
Heraeus -172mm
249 -215mm
Default -half the board length
Maximum
No adapter +255mm
255 +230mm
Sanyo +210mm
Heraeus +172mm
249 +215mm
Default +half the board length
Paste stop This parameter determines the stop position of the paste dispense measured from the
centre line of the machine. The maximum value depends on the type of screen fitted.
Minimum
No adapter -255mm
255 -230mm
Sanyo -210mm
Heraeus -172mm
249 -215mm
Default -half the board length
Maximum
No adapter +255mm
255 +230mm
Sanyo +210mm
Heraeus +172mm
249 +215mm
Default +half the board length
Knead Boards This parameter sets the number of boards to be printed using the knead sequence.
Minimum 1
Maximum 10
Increment 1
Knead Deposits This parameter sets the number of print strokes to be carried out on each of the kneaded
boards.
Minimum 2
Maximum 20
Increment 1
Paste Knead Period This parameter sets the time period between print cycles which, if exceeded, initiates a
paste knead sequence.
Minimum 0 (paste kneading switched off)
Maximum 30 minutes
Increment 1 minute
Knead After Dispense If this option is enabled and a paste dispense has been performed (either Manual or
Automatic) a paste knead is performed (as defined by the paste knead parameters in the
board file) on the next board immediately following the paste dispense.
ENABLED; DISABLED
Paste While Clean This parameter enables the machine to carry out a paste dispense while cleaning the
screen. Available modes are:
DISABLED, MODE 1, MODE 2, BOTH MODES
1.102 User Manual Software Version 6
MACHINE PROGRAMMING
MENU PARAMETERS