ERROR MESSAGES INTRODUCTION If for any reason the machine does not complete a particular sequence in the time allowed for in software, an error condition arises. The relevant error message is displayed on the main contro…

100%1 / 378
ERROR MESSAGES
INTRODUCTION If for any reason the machine does not complete a particular sequence in the time
allowed for in software, an error condition arises. The relevant error message is
displayed on the main control screen.
Machine Errors are detected by sensors specifically designed for checking
correct machine status (System Power, Pneumatic Power, etc.) or by functions
failing to achieve their correct operation. These latter errors are either detected
by a limit sensor being operated or by setting a time limit for their completion.
The time limits are set so they are 1.5 times the longest possible time taken for
that particular operation, after which, if not completed, an error is reported on the
main control screen.
When an error occurs the relevant message is displayed on the main control
screen. The displayed error message is accompanied by information regarding
the possible causes and the corrective action to be taken.
The Tricolour beacon changes to red and records the error in the Event Log file.
Software Version 6 User Manual 4.1
ERROR MESSAGES
INTRODUCTION
ERROR RECOVERY
When an error message is displayed the following options maybe available to
recover the machine:
Abort Pressing this option re-initializes the entire printer, ejecting any product that may
be in the printer and returning to the main control page.
Retry Selecting this option re-checks the error condition and if clear continues the print
cycle.
Recover Pressing this option attempts to continue with any cycle that is in operation. This
function sets modules (paste dispenser, print carriage, etc.) to their home
position and ejects the board that is currently in the printer without re-initializing
the machine. This option should be the first to be operated if there is an error
reported.
Diagnostics This option enables the diagnostics to be entered immediately, normally by a
technician, for more in-depth investigation of the problem.
Open Cover This option allows the operator to select Change Screen to gain access to the
tooling area of the machine.
Continue When this option is available, selecting the continue key clears the error message
and continue with the cycle that is in operation.
Fiducial Setup When this option is available, selecting the Fiducial Setup key allows the user to
relearn the reported ‘Not Found’ fiducial.
Auto Search When this option is available, selecting the Auto Search key instigates a search
within the selected window size to locate the ‘Not Found’ fiducial.
Search Step When this option is available, selecting the Search Step key moves the camera
the first step in a search procedure designed to locate the ‘Not Found’ fiducial.
Further selection of the key moves the camera to the second step etc. Once the
fiducial is visible in the region of interest, the Retry key can be selected to
capture the fiducial.
Search Reset When this option is available, selecting the Search Reset key returns the camera
to its original position, before the Search Step key was selected. This is the
position from which the ‘Not Found’ fiducial was reported.