Horizon UserManualV6.pdf - 第292页

Parameter Definition Low Paste Action This parameter sets the action performed on a low paste alarm. The options are: Manual Re-print Default - Manual Inspect After Clean This parameter sets whether a screen is inspected…

100%1 / 378
MENU PARAMETERS
Parameter Definition
2D Inspect Rate This parameter sets the number of print cycles between inspection cycles,
with zero indicating no inspection.
Minimum - 0
Maximum - 100
Increments - 1
Default - 0
Stencil Inspect Type This parameter sets the extent of the screen inspection. The options are:
None
Basic
Advanced
Default - Basic
Board Inspect Type This parameter sets the extent of the board inspection. The options are:
None
Basic
Advanced
Default - Basic
Pre-image This parameter sets when a pre-image is taken. The options are:
One - The first board only
Every - Every board
Default - One
Min Sites/Cycle This parameter sets the number of sites to inspect every cycle.
Minimum - Number of Every Cycle sites
Maximum - Total number of sites
Increments - 1
Default - Number of every cycle sites
Warning Limit This parameter determines how many consecutive warnings on the same
site constitute an alarm.
Minimum - 1
Maximum - 20
Increments - 1
Default - 3
Blockage Action This parameter sets the action performed on a blockage alarm. The
options are:
Manual
Automatic
Default - Manual
Blockage Clean This parameter sets the type of screen clean performed on blockage
alarm. The options are:
Mode 1
Mode 2
Default - Mode 1
Smear Action This parameter sets the action performed on a smear alarm. The options
are:
Manual Action
Automatic
Default - Manual
Smear Clean This parameter sets the type of screen clean performed on a smear alarm.
The options are:
Mode 1
Mode 2
Default - Mode 2
Software Version 6 User Manual 8.41
2Di INSPECTION
MENU PARAMETERS
Parameter Definition
Low Paste Action This parameter sets the action performed on a low paste alarm. The
options are:
Manual
Re-print
Default - Manual
Inspect After Clean This parameter sets whether a screen is inspected before the next board is
printed following a screen clean. The options are:
Disabled
Enabled
Default - Disabled
Post Print Alignment This parameter sets whether post print alignment is carried out. The
options are:
Not Performed
Performed
Default - Not Performed
No. Sites This parameter displays the total number of sites.
Minimum - 0
Maximum - 500
Increments - 1
Default - 0
Site Name The unique uppercase name given to a site for identification and which
cannot be mistaken for the name of a created site. The name can have a
maximum of 20 characters.
Site Priority This parameter determines the priority of a site. Where the site is part of
a device, the value applies to the whole device. The options are:
Not Inspected
General
Every Cycle
Default - Every Cycle
Site Alignment This parameter sets what alignment data is reported for each site. The
options are:
X & Y
X Only
Y Only
None
Default - None
Limit Set ID The unique uppercase name given to a set of limits which can be applied
to any site. This enables different sites to be inspected according to
different limits. The name can have a maximum of 20 characters. A
maximum of 14 limit sets can be created.
Paste Scaling This parameter enables adjustment of the paste scaling value for the
current site, to cause the value of paste present on the pad, currently
selected in the inspection list, to be reported as 100%. This parameter is
used in conjunction with the Auto Scale function.
Minimum - 0.01
Maximum - 2.00
Increments - 0.01
Default - 1
Site X Coord The coordinate of a site taken from the front left corner of the board, in
the X direction.
Minimum - 0.0mm
Maximum - Board Length
Increments - 0.1mm
Default - 164.1mm
8.42 User Manual Software Version 6
2Di INSPECTION
MENU PARAMETERS
Parameter Definition
Site Y Coord The coordinate of a site taken from the front left corner of the board, in
the Y direction.
Minimum - 0.0mm
Maximum - Board Width
Increments - 0.1mm
Default - 59.5mm
Site Width The width of the site to be inspected.
Minimum - 0.5mm
Maximum - 4.0mm
Increments - 0.01mm
Default - 0.7mm
Site Height The height of the site to be inspected.
Minimum - 0.5mm
Maximum - 6.5mm
Increments - 0.01mm
Default - 4mm
Blockage Warning This parameter sets the amount of aperture blockage required to initiate a
warning.
Minimum - 0%
Maximum - 100%
Increments - 1%
Default - 10%
Blockage Alarm This parameter sets the amount of aperture blockage required to initiate
an alarm.
Minimum - 0%
Maximum - 100%
Increments - 1%
Default - 20%
Smear Warning This parameter sets the amount of screen smear required to initiate a
warning.
Minimum - 0.01 sq. mm
Maximum - 10 sq. mm
Increments - 0.01 sq. mm
Default - 0.1 sq. mm
Smear Alarm This parameter sets the amount of screen smear required to initiate an
alarm.
Minimum - 0.01 sq. mm
Maximum - 10 sq. mm
Increments - 0.01 sq. mm
Default - 0.2 sq. mm
Paste warning This parameter sets the amount of paste on pad required to initiate a
warning.
Minimum - 0%
Maximum - 100%
Increments - 1%
Default - 90%
Paste Alarm This parameter sets the amount of paste on pad required to initiate an
alarm.
Minimum - 0%
Maximum - 100%
Increments - 1%
Default - 80%
Software Version 6 User Manual 8.43
2Di INSPECTION
MENU PARAMETERS