Horizon UserManualV6.pdf - 第268页
Edit Global 1. Select Edit Global . Edit Global Edit Limits Delete Site Next Site Previous Site Edit Site Inspect Site Exit NOTE Delete site is only available if at least one site exists already. Next site and previous s…

17. Select Run.
Run
Open
Cover
Paste
Load
Clean
Screen
Adjust Setup Monitor Maint.
18. If the screen has not been changed the message ‘Screen has not been
changed for this product’ is displayed, select Use Screen to continue.
19. Select Auto Board.
Auto
Board
Manual
Board
Knead
Paste
Exit
20. The message ‘Load board’ is displayed. Load board, select Confirm when
the board is loaded.
Confirm
Exit
21. Setup the board and screen fiducials.
22. Select Inspect Setup. If this option is unavailable, check set prefs for 2D
Inspection enabled.
Step Open
Cover
Inspect
Setup
Single Exit
NOTE
The windows in this procedure show the parameters and options available with
both screen and board inspect type set to advanced. If screen or board inspect
type is set to basic or none, certain parameters and options are not displayed.
CAUTION
FIDUCIAL POSITION. If during the print cycle, the position of board
fiducials are changed, the position of previous inspection sites (if any) may
be affected. Small changes are automatically compensated for, however
large changes, ie more than 3mm, require sites to be repositioned.
Software Version 6 User Manual 8.17
2Di INSPECTION
2Di SETUP
2D INSPECT RATE
STENCIL INSPECT TYPE
BOARD INSPECT TYPE
PRE-IMAGE
MIN SITES/CYCLE
WARNING LIMIT
BLOCKAGE ACTION
BLOCKAGE CLEAN
SMEAR ACTION
SMEAR CLEAN
LOW PASTE ACTION
INSPECT AFTER CLEAN
POST PRINT ALIGNMENT
No. SITES
1
ADVANCED
ADVANCED
EVERY
10
3
MANUAL ACTION
MODE 1
MANUAL ACTION
MODE 2
RE-PRINT
ENABLED
PERFORMED
30
Global Inspect Parameters
SITE NAME
SITE PRIORITY
STENCIL INSPECT TYPE
BOARD INSPECT TYPE
SITE ALIGNMENT
LIMIT SITE I.D.
PASTE SCALING
SITE X COORD
SITE Y COORD
SITE WIDTH
SITE HEIGHT
QFP 1
GENERAL
ADVANCED
ADVANCED
X AND Y
FINE
1.00
84.5 mm
89.5mm
4.00 mm
4.00 mm
Site Parameters

Edit Global 1. Select Edit Global.
Edit
Global
Edit
Limits
Delete
Site
Next
Site
Previous
Site
Edit
Site
Inspect
Site
Exit
NOTE
Delete site is only available if at least one site exists already.
Next site and previous site are only available if at least two sites exist already.
2. Enter the parameter values below using the Next, Previous, Incr. and Decr.
keys.
Limit
Options
Next Previous Incr. Decr.
Exit
• Pre-image to Every
• Min Sites to 10
•
Warning Limit to 20, this can be reduced later in ‘adjust inspect’.
•
Blockage Action to Manual, this can be changed later in ‘adjust inspect’.
•
Smear Action to Manual, this can be changed later in ‘adjust inspect’.
A definition of all 2Di parameters and their values is given at the end of this
chapter.
On completion of successful setup, parameters can be adjusted to suit the
product.
3. Select Limit Options.
Limit
Options
Next Previous Incr. Decr. Exit
8.18 User Manual Software Version 6
2Di INSPECTION
2Di SETUP
Advanced
Advanced
Every
10
3
Manual
Mode 1
Manual
Mode 2
Manual
Enabled
Performed
Stencil Inspect Type
Board Inspect Type
Pre-image
Min. Sites/Cycle
Warning Limit
Blockage Action
Blockage Clean
Smear Action
Smear Clean
Low Paste Action
Inspect After Clean
Post Print Alignment
Edit Global Parameters

These are usually set to enabled. If for any reason a particular inspection is not
required, set to disabled. If any global limit options are disabled the
corresponding limit sets and parameters are greyed out. These are global limits,
therefore they are active for the whole product. If a particular inspection is not
required for a specific type of site, this can be achieved later in limit set options.
4. Enter global limit options using Next, Previous, Incr. and Decr. keys.
Next Previous Incr. Decr.
Exit
5. Select Exit.
Next Previous Incr. Decr.
Exit
6. Select Exit.
Limit
Options
Next Previous Incr. Decr.
Exit
Edit Limits 1. Select Edit Limits.
Edit
Global
Edit
Limits
Delete
Site
Next
Site
Previous
Site
Edit
Site
Inspect
Site
Exit
The following window is displayed:
Software Version 6 User Manual 8.19
2Di INSPECTION
2Di SETUP
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
Blockage
Smear
Paste
Alignment
Bridging
Volume
Global Limit Set Options
Default
Default
10%
15%
0.01 sq mm
0.15 sq mm
90%
80%
0.02 mm
0.03 mm
0.05 mm
0.04 mm
80%
70%
Limit Set ID
BlockageWarning
BlockageAlarm
SmearWarning
SmearAlarm
PasteWarning
PasteAlarm
AlignWarning
AlignAlarm
BridgeWarning
BridgeAlarm
VolumeWarning
VolumeAlarm
Limit Sets
Limit Parameters