Horizon UserManualV6.pdf - 第211页
Raise Table to Print Height Selecting this diagnostic function first checks that the camera carriage is at home, if not at home the message ‘Table Movement Inhibited, Camera Not Home’ is displayed. If the camera is at ho…

RISING TABLE Selecting this diagnostics module opens the following window:
The menu bar changes to the following:
Run
Diagnost
Adjust Next Previous Exit
Next / Previous keys move the highlight bar up and down the list of selectable
diagnostic functions.
Run Diagnost activates the diagnostic function, as selected by the highlight bar.
Exit returns operation to the module diagnostics page.
Adjust opens the following window:
The menu bar changes to the following:
Next Previous Incr. Decr. Exit
Next / Previous keys have no function in this application.
Incr. / Decr. keys change the value of the cycle count.
Exit returns operation to the rising table diagnostics page.
Home Rising Table Selecting this diagnostic function drives the rising table down to the home
position, as indicated by its home sensor.
Raise Table to
Vision Height
Selecting this diagnostic function drives the rising table to the height set by the
vision height parameter.
5.28 User Manual Software Version 6
DIAGNOSTICS
RISING TABLE
R
i
s
i
ng Ta
bl
eD
i
agnost
i
cs
Rail Lifted Left
Rail Lifted Right
Table at Home
Cycle Count
ON
OFF
OFF
OFF
OFF
Done :-
0, To go :-
50
Home Rising Table
Raise Table to Vision Height
Raise Table to Print Height
Restore Default Heights
Set Reference Vision Height
Set Reference Print Height
Drive Table using Jog Buttons
Toggle Table Brake
Toggle Vacuum Tooling Valve
Cycle Rising Table
Table Cycle Test Parameters
CYCLE COUNT
50.0
Cycles

Raise Table to Print
Height
Selecting this diagnostic function first checks that the camera carriage is at
home, if not at home the message ‘Table Movement Inhibited, Camera Not
Home’ is displayed. If the camera is at home, the rising table drives up to the
height set by the print height parameter.
Restore Default
Heights
Selecting this diagnostic function restores the vision height to the default of 50
mm and the print height to the default of 127 mm.
Set Reference
Vision Height
Selecting this diagnostic function enables the rising table vision height to be set
so that the camera views the board fiducials in focus. This is achieved by driving
the table up or down while viewing the vision monitor until the fiducial is in
focus. Pressing Calibrate Vision Height changes the menu Bar showing the
option Confirm. Pressing Confirm sets the current height of the rising table,
updating the printer configuration file. Refer to the Technical Reference
Manual, Camera and Vision System Chapter for the camera reference position
procedure.
Set Reference Print
Height
Selecting this diagnostic function enables the print height to be set so that no gap
exists between the screen and board. Refer to the Technical Reference Manual,
Rising Table Chapter for the print height calibration procedure.
Drive Table Using
Jog Buttons
Selecting this diagnostic function enables the right jog button to drive the rising
table up at slow speed and the left jog button to drive the table down, stopping
immediately the button is released.
Toggle Table Brake Selecting this diagnostic function alternately switches the table brake on and off,
while continuously displaying the current status.
Toggle Vacuum
Tooling Valve
Selecting this diagnostic function alternately switches the vacuum tooling
solenoid on and off, to supply and remove pneumatic pressure to the venturi
vacuum pump, continuously displaying the current status.
Cycle Rising Table Selecting this diagnostic function first checks that the camera carriage is at
home, if not the message ‘Table Movement Inhibited, Camera Not Home’ is
displayed. If the camera is at home, a continuous cycle starts driving the rising
table to print height, dwelling for 2 seconds, driving the table down to its datum
height, dwelling for 2 seconds and repeating the cycle until stop is pressed or the
set cycle count has been reached.
Rail Lifted Left This diagnostic function continuously displays the status of the rail lifted left
sensor. Off is displayed when the rail has been lifted.
Rail Lifted Right This diagnostic function continuously displays the status of the rail lifted right
sensor. Off is displayed when the rail has been lifted.
Software Version 6 User Manual 5.29
DIAGNOSTICS
RISING TABLE

Table at Home This diagnostic function continuously displays the status of the home interlock
sensor. On is displayed when the rising table is in the home position.
Cycle Count This diagnostic function displays the amount of cycles done and the amount of
cycles to go to complete the cycle count.
5.30 User Manual Software Version 6
DIAGNOSTICS
RISING TABLE