IP ADDRESS CONFIGURATION
For a machine to function in a network environment, correct setting of its IP
Address is necessary. The IP Address (Internet Protocol Address) provides a
unique global address for both the machine and the network.
NOTE
IP Addresses must be provided by the sites Line or Network Manager.
TCP/IP Driver
(GEM and
NET_FILES)
Windows NT Network Configuration option can be set up using the Network
icon in Control Panel. Select Protocols and highlight TCP/IP Protocol. From
Properties choose the appropriate adaptor and either obtain or specify a IP
address for the printer.
SDR Driver
(GEM Only)
The IP address of the printer must be set up in the SDR driver. To do this edit the
SDR configuration file ‘c:\printer\conf170.cfg’ (see next page) using a text
editor. The DOS program EDIT is suitable and can be used by typing the
following from the DOS prompt:
EDIT C:\printer\conf170.cfg
Set the PASSIVE ENTITY IPADDRESS to the printers ‘IP address’.
If there is more than one printer communicating with the GEM Host, set the
DEVICEID differently for each printer. The default value is 0x109 (265).
Alternative DEVICEID values should be chosen within the range
0x0000 - 0x7FFF (0 - 32767).
3.4 User Manual Software Version 6
HOST COMMUNICATIONS
IP ADDRESS CONFIGURATION
Configuration File /* SDR-DOS-170 Sample Configuration File*/
PORT 0:
PROTOCOL HSMS94
EQUIPMENT
PASSIVE ENTITY
PASSIVE ENTITY IPADDRESS 192.100.20.51
PASSIVE ENTITY TCPPORT 5265
T3 30
T5 5
T6 10
T7 5
T8 6
CONNECTION ESTABLISHMENT 5
CIRCUIT ASSURANCE 20
TGRACE 15
MEMORY STALL 5
WRITE STALL 7
START
DEVICE 0:
DEVICEID 0x109
PORT 0
START
Definitions of Fields The majority of the fields in the SDR configuration file never need to be
changed. They are described here to give an understanding of how to configure
the driver when changing IP addresses, Device ID’s or some of the timer values.
Port 0: Defines this port as SECS port 0.
Protocol HSMS94 Selects the protocol that the SDR driver uses.
Equipment Defines that the printer end of the link is the equipment end.
Software Version 6 User Manual 3.5
HOST COMMUNICATIONS
IP ADDRESS CONFIGURATION
Passive Entity Defines that the printer is the passive entity and that the host is expected to
establish the TCP/IP connection. A GEM host is almost always the active entity.
Passive Entity IP
Address
Sets the IP address of the printer.
Passive Entity TCP
Port
Specifies a TCP Port number at which the passive entity waits for a connection
on this HSMS link. Typically a number beginning at 5000.
T3 30 Sets the HSMS-SS T3 reply time-out to 30 seconds. If the printer does not
receive a reply within this time a S9F9 Transaction time-out error message is
transmitted.
T5 5 The HSMS-SS T5 Connect separation Timer value. Only used by an ‘ACTIVE’
entity.
T6 10 The HSMS-SS T6 Control Message Reply Timer value. should be less than T3
10 is a typical value.
T7 5 The HSMS-SS T7 Connect time-out value. The time that the PASSIVE Entity
waits to receive a HSMS Select.req control message after a TCP/IP connection
has been established. If the time is exceeded the TCP/IP link is terminated.
T8 6 The HSMS-SS T8 Inter-character Timer value. The maximum time that SDR
driver waits for a TCP/IP recv operation to complete. If the time is exceeded the
TCP/IP link is terminated.
Connection
Establishment 5
Only used by an ‘ACTIVE’ entity.
Circuit Assurance 20 Defines the frequency at which the SDR Driver initiates a HSMS Linktest
control transaction.
T Grace 15 A period during the start up of the link. when the SDR Driver accepts and
buffers messages from the printer software.
Memory Stall 5 This limits how long the SDR Driver tolerates a situation where all of its buffers
are full and the host is attempting to send more data. If the time is exceeded the
TCP/IP link is terminated.
3.6 User Manual Software Version 6
HOST COMMUNICATIONS
IP ADDRESS CONFIGURATION