Horizon UserManualV6.pdf - 第290页

IMAGE RECORDING Selecting Save Image saves the inspection object data using the save object command. This option is only available if image recording in set preferences is set to VP or PC disk. If the image recording is …

100%1 / 378
Inspect All Selecting this option clears the alarm panel and changes the beacon back to
green. The inspection sequence is restarted from the beginning. All the existing
alarm information is cleared.
Adjust Inspect Selecting this option displays the following menu:
Edit
Global
Edit
Limits
New Pre-
images
Edit
Site
Inspect
Site
Exit
Edit Global Selecting this option opens the edit global parameters window, allowing
parameters that are used throughout the inspection to be altered.
Edit Limits Selecting this option opens the limit sets window, allowing a set of limit
parameters to be selected and altered.
New Pre-images Selecting this option initiates a pre-print inspection on the next print cycle to
capture the new pre-images. The message ‘New pre-images will be collected
next print cycle’ is displayed.
NOTE
The New Pre-image button is only available if pre-image is set to 1.
Edit Site Selecting this option opens the site parameters window, allowing adjustment of
the site specific parameters.
Inspect Site Selecting this option opens the inspection results window and displays the
following menu:
Auto
Scale
Toggle
Paste
Next Previous Exit
Selecting Next or Previous moves the highlight up and down the list of site pads.
Selecting Toggle Paste either shows or hides the paste display overlay onto the
monitor. The toggle paste facility on the board image is only functional with the
board inspection type set to advanced. Toggling paste on the screen is only
available on Horizon and Infinity machines and only with the screen inspect type
set to basic or advanced.
Selecting Auto Scale automatically adjusts the paste scaling value for the
current site, to cause the value of paste present, on the pad currently selected in
the inspection result list, to be reported as 100%. This is used where the site pad
causing the alarm is actually a good print.
Reject Selecting this option clears the alarm panel and the board is fed to the output end
of the rail system and held there.
Software Version 6 User Manual 8.39
2Di INSPECTION
OPTIONS AFTER AN INSPECTION ALARM
IMAGE RECORDING
Selecting Save Image saves the inspection object data using the save object
command. This option is only available if image recording in set preferences is
set to VP or PC disk. If the image recording is set to VP disk, the file name is
inspnnn.img, where nnn is the next sequence number to save. If the image
recording is set to PC disk, the file name is inspn.img, where n is a number
cycling from 1 to 5. The first image saved after initialization is insp1.img. Files
are overwritten without warning.
NOTE
VP disk saves to the Cognex HD if fitted. It is recommended to use PC disk only
for image recording.
8.40 User Manual Software Version 6
2Di INSPECTION
IMAGE RECORDING
MENU PARAMETERS
Parameter Definition
2D Inspect Rate This parameter sets the number of print cycles between inspection cycles,
with zero indicating no inspection.
Minimum - 0
Maximum - 100
Increments - 1
Default - 0
Stencil Inspect Type This parameter sets the extent of the screen inspection. The options are:
None
Basic
Advanced
Default - Basic
Board Inspect Type This parameter sets the extent of the board inspection. The options are:
None
Basic
Advanced
Default - Basic
Pre-image This parameter sets when a pre-image is taken. The options are:
One - The first board only
Every - Every board
Default - One
Min Sites/Cycle This parameter sets the number of sites to inspect every cycle.
Minimum - Number of Every Cycle sites
Maximum - Total number of sites
Increments - 1
Default - Number of every cycle sites
Warning Limit This parameter determines how many consecutive warnings on the same
site constitute an alarm.
Minimum - 1
Maximum - 20
Increments - 1
Default - 3
Blockage Action This parameter sets the action performed on a blockage alarm. The
options are:
Manual
Automatic
Default - Manual
Blockage Clean This parameter sets the type of screen clean performed on blockage
alarm. The options are:
Mode 1
Mode 2
Default - Mode 1
Smear Action This parameter sets the action performed on a smear alarm. The options
are:
Manual Action
Automatic
Default - Manual
Smear Clean This parameter sets the type of screen clean performed on a smear alarm.
The options are:
Mode 1
Mode 2
Default - Mode 2
Software Version 6 User Manual 8.41
2Di INSPECTION
MENU PARAMETERS