Horizon UserManualV6.pdf - 第177页

Error Message Interpretation Failed to Determine Tooling Deviation This error reports that while monitoring the tooling deviation, the number of samples (pressure variations) during the print stroke was less than 2 or th…

100%1 / 378
Error Message Interpretation
Command Timed Out
(Camera Axes)
This error reports that the camera has failed to move to the
demanded position within the time period. This error
applies to both the X and Y camera axis. Possible causes
are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
NextMove card faulty.
Command Timed Out
(Paste Dispense Carriage)
This error reports that the paste dispense carriage has failed
to move to the demanded position within the time period.
Possible causes are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
NextMove card faulty.
Command Timed Out
(Print Carriage)
This error reports that the print carriage has failed to move
to the demanded position within the time period. Possible
causes are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
NextMove card faulty.
Command Timed Out
(Proflow)
This error reports that the proflow unit has failed to move to
the demanded position within the time period. Possible
causes are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
NextMove card faulty.
Command Timed Out
(Rail System)
This error reports that the moving rail has failed to move to
the demanded position within the time period. Possible
causes are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
NextMove card faulty.
Command Timed Out
(Screen Actuators)
This error reports that the actuator has failed to move to the
demanded position within the time period. Possible causes
are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
NextMove card faulty.
Command Timed Out
(Front/Rear Squeegee)
This error reports that the front/rear squeegee has failed to
move to the demanded position within the time period.
Possible causes are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
NextMove card faulty.
Downline Board Transfer
Fault
This error reports that the time the downline interface has
waited for a board has exceeded the time-out.
Downline Machine Not
Available
This error reports that the downline machine is unavailable
to accept the next board.
Event File Open Error This error reports that there was a problem opening the
event log backup file.
4.4 User Manual Software Version 6
ERROR MESSAGES
ERROR MESSAGE LISTING
Error Message Interpretation
Failed to Determine
Tooling Deviation
This error reports that while monitoring the tooling
deviation, the number of samples (pressure variations)
during the print stroke was less than 2 or the minimum
value was zero. This error message is only valid where
tooling deviation is authorized and enabled.
Check tooling support is sufficient.
Check underside components are clear of tooling.
Front Squeegee Error This error reports that the front squeegee has failed to reach
its fully up position.
Front Squeegee Pressure
Error
When this error is detected a new window displays the set
pressure reading and the actual pressure reading.
File Error This message appears if there is an error writing or reading
a 265 file.
Have All Tooling Pins
Been Removed ?
This message appears for the user to confirm that all
magnetic tooling pins have been removed, before setting up
the machine for a new board file that uses AutoFlex tooling.
Invalid Calibration Data.
Recalibrate ProFlow
Heights
This error reports that the ProFlow calibration data is
corrupt or invalid.
Invalid Calibration Data.
Recalibrate Squeegee
Heights
This error reports that the squeegee calibration data is
corrupt or invalid.
Lid Bolt Fault This indicates that the lid bolt has failed to either open or
close.
No Paste Knead Cycles
Selected
This error reports when Knead Paste is selected on main
menu page and Knead Deposits in Set Prefs is selected to 0
cycles.
Paste Carriage Error This error reports that the paste carriage has failed to reach
its home position.
Paste Cartridge Tilt Error This error reports that the paste cartridge mechanism has
failed to either make its up or down limit switches.
Pneumatic Power Down This error message reports that the pneumatic supply is
either too low or has been disconnected.
Position Error
(Camera)
This error reports that the cameras actual position is not
within the tolerance of 1% of the designated position.
Position Error
(Print Carriage)
This error reports the print carriage actual position is not
within tolerance of its designated position.
Position Error
(Rising Table)
This error reports that the rising table has failed to reach its
home position.
Print Carriage Error This error reports that the print carriage has failed to move.
Proflow Downstop At
Limit
This error reports when the downstop reaches set limits
whilst using the jog buttons in Diagnostics, Drive
Downstop Using Jog Buttons.
Proflow at Movement
Limit
This error reports when the proflow reaches set limits
whilst using jog buttons in Diagnostics, Drive System
Using Jog Buttons.
Software Version 6 User Manual 4.5
ERROR MESSAGES
ERROR MESSAGE LISTING
Error Message Interpretation
Rail Lifted Error, Check
Tooling
This error reports that either the left rail lifted sensor or the
right rail lifted sensor are out of their home positions when
any of the following moves are taking place:
Alignment of the screen
Board stop moving into position
Initialization of the machine
Initialization of the AutoFlex tooling
Possible causes are:
A misfed board
Tooling/object on the rising table striking the underside of
the rails
Rear Squeegee Error This error reports that the rear squeegee failed to reach its
fully up position.
Rear Squeegee Pressure
Error
When this error is detected a new window displays the set
pressure reading and the actual pressure reading.
Rising Table Error This error reports that the rising table has either failed to
reach its fully down position or that when attempting to
reach the required height during the machine cycle did not
achieve the positional accuracy.
Rising Table Out of
Position
This error reports that either; the camera axes are not at the
home position when the rising table is to be lifted, or the
rising table is at a height greater than vision height by 1mm.
Screen Cleaner Out Of
Position
This error reports that the screen cleaner is out of position.
Possible causes are:
Screen Cleaner not at the home position.
Home sensor - enter Diagnostics, Digital Inputs and check
the sensor changes state.
If a screen cleaner is not fitted, check that the home sensor
is not connected.
Screen Couplings Not
Extended
This error reports that the screen couplings have failed to
extend within the 4 second time-out period.
Screen Fiducial Not Found This error reports that the vision system has been unable to
locate the screen fiducial.
Screen XF Error This error reports that the X forward screen actuator failed
to initialize to its central datum.
Screen XR Error This error reports that the X rear screen actuator failed to
initialize to its central datum.
Screen Y Error This error reports that the Y screen actuator failed to
initialize to its central datum.
Set Pressure %2.21f Actual
Pressure %2.21f
(Front/Rear Squeegee)
This error reports if the front/rear squeegee pressure differs
from the pressure set by more than ± 1.00Kg.
Stop After Idle Time
Exceeded
This error reports if the idle time is exceeded, the options to
continue or abort are displayed. Continue resets the idle
timer or abort allows for Manual or Auto unload.
System Power Down This error reports that the 24V motor power has been
switched off either by the Emergency Stop button being
activated (including upline and downline external
machines) or that the removable frame access cover has
been removed
4.6 User Manual Software Version 6
ERROR MESSAGES
ERROR MESSAGE LISTING