00198243-01_AI_BulkFeederX_XS-SX_DE+EN.pdf - 第121页

4 Retrofit kit for X-Series S 4.4 Inserting the cable into the machine Assembly Instructions / Montageanleitung SIPLACE BulkFeeder X Retrofit Kit for SX Series and X Series S 07/2017 121 4.4.2 Location 2 and 3 Insert the…

100%1 / 148
4 Retrofit kit for X-Series S
4.4 Inserting the cable into the machine
120 Assembly Instructions / Montageanleitung SIPLACE BulkFeeder X Retrofit Kit for SX Series and X Series S 07/2017
4.4 Inserting the cable into the machine
One BulkFeeder X can be connected at each location.
At location 4, you can connect the BulkFeeder X directly to the BulkFeeder X computer with
the cable [03151338-xx] (length 2 m).
To connect the Bulkfeeder X to locations 1, 2 and 3, you first need to insert the cable into the
machine.
 NOTICE!
When inserting the cable, pay attention to the labeling on the cable ends to make sure
you connect correctly: "* BF *" for the BulkFeeder X; "* GigE *" for the BulkFeeder X
computer
.
4.4.1 Location 1
Insert the cable [0312556-xx] (length 4 m) for connecting the BulkFeeder X at location 1 as follows:
Pull the cable (1) from location 4 via the conveyor
side to location 1.
4 Retrofit kit for X-Series S
4.4 Inserting the cable into the machine
Assembly Instructions / Montageanleitung SIPLACE BulkFeeder X Retrofit Kit for SX Series and X Series S 07/2017 121
4.4.2 Location 2 and 3
Insert the cable [03159498-xx] (length 7.5 m) for connecting the BulkFeeder X at location 2 or 3 as
follows:
Pull the cable (1) at location 4 under the fitted
Bulkfeeder X computer through the conveyor side
and towards the back.
Run the cable to the left under the machine base,
through the bottom of the machine and to loca-
tion 1.
4 Retrofit kit for X-Series S
4.4 Inserting the cable into the machine
122 Assembly Instructions / Montageanleitung SIPLACE BulkFeeder X Retrofit Kit for SX Series and X Series S 07/2017
Use the opening in the bottom of the machine to
pull the cable.
Run the cable (1) from location 1 via the machine
base to placement area 2.
Run the cable (1) at location 2 or 3 through the
opening in the machine base to the conveyor
side.