N7201A616E00_0317.pdf - 第296页
NPM-W 2 EJM7DE-MB-04O-0 0 Error Cnt Err Rate InspectNum CompName The numb er of comp onents judged as defective in inspec tion. (The number of errors/ the number of inspection ) x 100(%) 4-4-3 -5 Inspection monitor 3 Ope…

NPM-W2 EJM7DE-MB-04O-00
4-4-3-4
I
J
K
G
H
Selects the NG location of the first
component.
Switches between lanes. After a PCB is
unloaded;
●If the inspection result of a selected
lane is OK and if the inspection result
of the opposed lane is NG, it switches
to the opposed lane because higher
priority is given to NG information.
●When the inspection results of both
lanes are either OK or NG, it is not
switched over to the other lane.
Switches between component and solder
inspection maps, and displays the
current inspection map.
●When the map can be switched
between component and solder
inspection maps, the component
inspection map is displayed in
preference to solder inspection map.
(Returns to production condition)
●The signal tower turns green.
●The buzzer stops sounding.
Displays information on solder defect
judgment on the next component.
Component
inspection

NPM-W2 EJM7DE-MB-04O-00
Error Cnt
Err Rate
InspectNum
CompName
The number of components judged as
defective in inspection.
(The number of errors/ the number of
inspection ) x 100(%)
4-4-3-5
Inspection monitor 3
Operating procedure
4-4-3
Produc-
tion
Component
A
B
C D E
1
F
A
B
D
E
C
F
Chip
In the cases such as these, where certain components produce a high concentration of defects, the
components judged as defective are checked on a per-component basis so that they are utilized to identify
and take measures against the causes of defects.
Scrolls to display a long component name.
Switches between component inspection
and solder inspection.

NPM-W2 EJM7DE-MB-04O-00
4-4-3-6
BA C D E F G
Returns to the previous screen.
1
H
H
A
B
E
F
C
D
G
(Displays detailed error information)
Foreign body
Different component
Flip-over
The number of flip-over inspection errors.
Presence/absence
The number of foreign body inspection
errors.
The number of different component
inspection errors.
(Currently not in use)
Position
Polarity
The number of polarity inspection errors.
Other
The number of other errors.
The number of presence/absence
inspection errors.
The number of displacement inspection
errors.
Component
inspection