N7201A616E00_0317.pdf - 第624页

NPM-W 2 EJM7DE-MB-07 O-00 Machine parame- ter Operating procedure 7-3-12 7-3-12 A B C A B C Lamp value of fset ch e ck (inspection head) You can check the offset value (calibration result) of the inspection head light un…

100%1 / 714
NPM-W2 EJM7DE-MB-07O-00
Machine
parame-
ter
Operating procedure
7-3-11
7-3-11
A
A
B C
B
C
Shading offset
Corrects brightness of the inspection
area to be even.
White balance
Registers the adjusted color tone of the
inspection area.
Head camera
information check
(inspection head)
You can check the offset value (calibration result) of the inspection head camera unit.
Distortion offset
Corrects light distorted inner or outer
side through a lens
System
administration
NPM-W2 EJM7DE-MB-07O-00
Machine
parame-
ter
Operating procedure
7-3-12
7-3-12
A
B
C
A
B C
Lamp value offset
check (inspection head)
You can check the offset value (calibration result) of the inspection head light unit.
Lamp offset value
Displays a previous or next table.
Standard light value
For component inspection
0 / 128 /128 /128
For solder inspection
30 / 0 / 0 / 200
NPM-W2 EJM7DE-MB-07O-00
Machine
parame-
ter
Operating procedure
7-3-13
7-3-13
A
A
Four points offset
check (inspection head)
You can check the offset value (calibration result) when the inspection head moves to the XY standard mark
position.
For dual conveyor, choose a lane 1 in advance. (For how to switch the lane(P.2-2-1-9 ‘Lane switch button’))
Standard mark coordinates
X[mm]/Y[mm]
Offset values of the inspection head on
XY coordinates of a transport conveyor
standard mark.
System
administration