N7201A616E00_0317.pdf - 第342页
NPM-W 2 EJM7DE-MB-05O-0 0 Inspection map Denominator/Numerator Denominato r: The order of the displayed inspection NGs . Numerator: The total number of inspection NGs . Comment Pattern No Parts info The name of the pla c…

NPM-W2 EJM7DE-MB-05O-00
5-4-3-2
Solder
inspection

NPM-W2 EJM7DE-MB-05O-00
Inspection map
Denominator/Numerator
Denominator: The order of the displayed
inspection NGs.
Numerator: The total number of
inspection NGs.
Comment
Pattern No
Parts info
The name of the placement component .
Inspection monitor 2
Operating procedure
5-4-3
Produc-
tion
1
A
B
D
E
F
C
5-4-3-3
1
F E
A
BCD
G H
K
ML
I J
Check the NG location of the last NG PCB unloaded on the map.
The details of the NG location can be checked by displaying the nature or cause of the defect or enlarging the
display of the NG location map.
●Do not press the foot switch of the conveyor before completing the inspection or repair of the NG location.
If the next PCB happened to be unloaded, the map would also be updated based on the information on the
next PCB.
●When an inspection results in NG, a PCB, after being ejected, comes to rest on the ejection conveyor. Also,
the signal tower blinks and a buzzer sounds.
Explanation of the screen
■Where inspection results in NG
■Where inspection results in OK
■Where defect is yet to be inspected
Displays the NG location on a PCB on
the map.
●Touching the screen enlarges a
selected defect, with a focus on the
defect.
Bad item
Displays other defective items.

NPM-W2 EJM7DE-MB-05O-00
G
H
Selects the NG location of the first
component.
5-4-3-4
J
I
K
L
M
Switches between component and solder
inspection maps, and displays the
current inspection map.
●When the map can be switched
between component and solder
inspection maps, the component
inspection map is displayed in
preference to solder inspection map.
(Returns to production condition)
●The signal tower turns green.
●The buzzer stops sounding.
Displays information on solder defect
judgment on the next component.
Displays information on solder defect
judgment on the next identical
component.
Displays information on solder defect
judgment on the last identical component.
Switches between lanes. After a PCB is
unloaded;
●If the inspection result of a selected
lane is OK and if the inspection result
of the opposed lane is NG, it switches
to the opposed lane because higher
priority is given to NG information.
●When the inspection results of both
lanes are either OK or NG, it is not
switched over to the other lane.
Solder
inspection