No. Item name Function when [ON] is selected
1
Production report
clear at auto product
change
Clears the production report at production changeover.
2
Production report
clear at the other lot
name auto product
change
Clears the production report only when changing production to a different lot
name.
The report is cleared also when the MJS ID differs.
3
Display transfer
direction of status
monitor PCB
Displays the PCB flow direction on the Status monitor screen.
4
Buzzer stop button
auto change
Changes the function button to [Buzzer stop] automatically when the buzzer
sounds.
5 PCB warp correction
Estimates the board warp based on the heights measured by sensor at
several points on the board, in order to control the mounting height.
No. Item name Function when [ON] is selected
1
Time-lapse change
calibration
Performs calibration for time-lapse change.
No. Item name Function when [ON] is selected
1
Vacuum sensor error
detection
Detects error by the vacuum sensor during automatic operation.
No. Item name Function when [ON] is selected
1
Nozzle center
measure
Measures the center of rotation and eccentricity of the nozzles used for
production by priming shot recognition during automatic operation in order to
improve the correction accuracy.
Setting information 12
Default ON
Whole (Suspension)
Default ON
XY-axes (Suspension)
Default ON
Head (Suspension)
Default ON
Dispensing head (Suspension)
Unit
setting
Option setting 7
Operating procedure
7-1-1
NPM-W2 EJM7DE-MB-07O-00
7-1-1-14
No. Item name Function when [ON] is selected
1 PCB in when stop
Prohibits the loading of next PCB from the upstream process during single
stop or cycle stop.
2 PCB out when stop
Carries out the PCB waiting in the machine to the downstream process
during single stop or cycle stop.
3 Wait between MC
Determines whether or not to have a PCB held in between the machines in
the line where the NPM is directly connected upstream or downstream the
machine.
4 Simultaneous transfer Enables PCB unloading and loading of the next PCB at the same time.
5
Support action time
being shortened
Lowers the support to the “both sides mount height”, and raises it after the
next PCB is loaded.
6
Keep clamping in
cycle stop
Keeps the clamp engaged during cycle stop.
7
Decelerate in the pre
waiting position while
carrying out
Activates the timer whenever a PCB is transferred from the thirdparty
conveyor to the loading conveyor, to allow the PCB to stop in the loading
conveyor.
No. Item name Function when [ON] is selected
1
Top tape error
detected
Detects top tape exhaust and tape jamming error.
2
Tape joint error
detect
Detects tape joint error.
3
Component remains
input
Allows the part remainder to be input manually after splicing.
No. Item name Function when [ON] is selected
1
Tray pre supply of
exceeding priority
Supplies pallets during inspection and prepares for the next mounting
preferentially when the inspection head and mount head have been set on
the machine and the order of their tasks has been fixed.
Setting information 13
Default ON
Conveyor (Suspension)
Default ON
Feeder (Suspension)
Default ON
Tray (Suspension)
System
administration
NPM-W2 EJM7DE-MB-07O-00
Unit
setting
Action parameter
setting 1
7-1-2-1
You can set the parameters for system actions.
1
2
A
B
Operating procedure
7-1-2
Choose the type of action
parameter
To set the size
To set the timer
To determine
Setting status of action
parameter
The previous or next table is
displayed.
Edit data on the screen as
needed
Touching the screen opens the input
window.
To set to PFSC standard specifications
(Initialize)
B
11 2
A